Main Menu Picture Function Setting for the picture quality. Item Exit Contrast Brightness Saturation Sharpness Hue Backlight To do Return Main Menu Adjusts the contrast of the display. Adjusts the brightness of the display. Adjusts the saturation of the display. Adjusts the sharpness of the display. Adjusts the hue of the display. Adjusts the backlight of the display. Setting value 0 to 100 0 to 100 0 to 100 0 to 100 0 to 100 0 to 100 Color Temperature Adjusts the R/G/B Gain and Bias, and Gamma Preset Item Exit Gamma Color Temp Red Gain Green Gain Blue Gain Red Bias Green Bias Blue Bias To do Return Main Menu Select the Gamma correction value. Select the color temperature Mode. Adjusts the Red Gain Adjusts the Green Gain Adjusts the Blue Gain Adjusts the Red Bias Adjusts the Green Bias Adjusts the Blue Bias Setting value 2.2 (equivalent to Υ 2.2) 2.4 (equivalent to Υ 2.4) 2.6 (equivalent to Υ 2.6) 5600Ka6500Ka9300KaUser 0 to 255 0 to 255 0 to 255 0 to 255 0 to 255 0 to 255 Only "Color Temp" is set to "User", the Red/Blue/Green Gain or Red/Blue/Green Bias can be adjusted Function Key Set short-cut functions for F1-F4 Item To do Setting value Exit Return Main Menu F1 F2 Audio Bar, False Color, AFD, H/V Delay, R/G/B/Mono, F3 F4 Assign functions to the function keys F1 - F5 on the front key board Marker , Color Bar, UMD, Audio Alarm, Focus Assist , Aspect Ratio , Scan Mode, Zoom Mode, Mute, Freeze Frame, Flip Mode , CVBS, YPbPr ,VGA , Color Temp, Time Code, Zebra. F4 For example: Set F3 to "Flip Mode" under "Function key" submenu. User can press F3 on the front panel to adjust the parameters of "Flip Mode", and the "Flip Mode" will change and follow the sequence: H Flip ¹V Flip¹H/V Flip ¹Off . ABCDEF ABCDEF ABCDEF ABCDEF GPI Setting functions for external control Item Exit GPI Control*1 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin To do Return Main Menu Enable GPI control Assign functions to the GPI terminals Setting value ON, OFF Red Tally, Green Tally, Yellow Tally, Aspect Ratio, Scan Mode, Zoom Mode, Mute, Freeze Frame, Flip Mode, Color Temp, Time code, Zebra,Audio Bar, False Color, AFD, H/V Delay, R/G/B/Mono, Marker , Color Bar, UMD, Audio Alarm, Focus Assist. *1 When "GPI control" is set to "On", the monitor can be operated through external GPI control unit. Example 1: Under "GPI " submenu, set "GPI control" to "On", set "2 Pin" to "Red Tally", when the pin 2 of the extenal GPI control unit is Example 2: Under "GPI " submenu, set "GPI control" to "On", set "6 Pin" to "Scan Mode", when the pin 6 of the extenal GPI control unit is 11 connected with ground, the Scan mode will change and follow the sequence: "Normal" ¹"Overscan"¹"Native" .

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

Main Menu
Picture Function
Setting for the picture quality.
Item
Exit
Contrast
Brightness
Saturation
Sharpness
Hue
Backlight
To do
Return Main Menu
Adjusts the contrast of the display.
Adjusts the brightness of the display.
Adjusts the saturation of the display.
Adjusts the sharpness of the display.
Adjusts the hue of the display.
Adjusts the backlight of the display.
Setting value
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
Item
Exit
Gamma
Color Temp
Red Gain
Green Gain
Blue Gain
Red Bias
Green Bias
Blue Bias
To do
Return Main Menu
Select the Gamma correction value.
Select the color temperature Mode.
Adjusts the Red Gain
Adjusts the Green Gain
Adjusts the Blue Gain
Adjusts the Red Bias
Adjusts the Green Bias
Adjusts the Blue Bias
Setting value
2.2 (equivalent to Υ 2.2)
2.4 (equivalent to Υ 2.4)
2.6 (equivalent to Υ 2.6)
5600K
6500K
9300K
User
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
Only “Color Temp” is set to “User”, the Red/Blue/Green Gain or Red/Blue/Green Bias can be adjusted
Item
Exit
F1
F2
F3
F4
F4
Setting value
To do
Return Main Menu
Assign functions to the function
keys F1 - F5 on the front key board
Item
Exit
GPI Control*1
1 Pin
2 Pin
3 Pin
4 Pin
5 Pin
6 Pin
Setting value
To do
Return Main Menu
Enable GPI control
Assign functions to the GPI
terminals
ON, OFF
*1 When “GPI control” is set to “On”, the monitor can be operated through external GPI control unit.
Example 1: Under “GPI ” submenu, set “GPI control” to “On”, set “2 Pin” to “Red Tally”, when the pin 2 of the extenal GPI control unit is
Example 2: Under “GPI ” submenu, set “GPI control” to “On”, set “6 Pin” to “Scan Mode”, when the pin 6 of the extenal GPI control unit is
connected with ground, the Scan mode will change and follow the sequence: “Normal”
”Overscan”
”Native” .
Color Temperature
Adjusts the R/G/B Gain and Bias, and Gamma Preset
Function Key
Set short-cut functions for F1-F4
GPI
Setting functions for external control
11
Audio Bar, False Color, AFD, H/V Delay, R/G/B/Mono,
Marker , Color Bar, UMD, Audio Alarm, Focus Assist ,
Aspect Ratio , Scan Mode, Zoom Mode, Mute, Freeze Frame,
Flip Mode , CVBS, YPbPr ,VGA , Color Temp, Time Code, Zebra.
Red Tally, Green Tally, Yellow Tally, Aspect Ratio, Scan Mode,
Zoom Mode, Mute, Freeze Frame, Flip Mode, Color Temp,
Time code, Zebra,Audio Bar, False Color, AFD, H/V Delay,
R/G/B/Mono, Marker , Color Bar, UMD, Audio Alarm, Focus Assist.
For example: Set F3 to “Flip Mode” under “Function key” submenu. User can press F3 on the front panel to adjust the parameters of