JVC KY-F1030U KY-F1030U digital camera 52 page instruction manual (550KB, PDF) - Page 44

SYSTEM SETTING screen

Page 44 highlights

5. Menu screen settings (continued) SYSTEM SETTING screen [ ] indicates the factory setting Item AE DISPLAY FRZ DISPLAY FRZ CANCEL TEST PATTERN LEVEL When "BAR"/ "IMPULSE" is selected MENU RESET Set Value [OFF] ON [ON] OFF [MANUAL] AUTO (1s) AUTO (3s) AUTO (5s) OFF [BAR] RAMP IMPULSE [0.7V] 0.57V Contents Used to set whether the ALC, EEI and IRIS values are displayed on the analog output screen. OFF: No on-screen-display ON: On-screen-display Used to set whether the "FREEZE" indicator is shown on the screen at the time of trigger input. ON: Displayed OFF: Not displayed Sets the method for canceling the FREEZE when the monitor screen is in FREEZE condition when connection is made through digital output. MANUAL : Cancelled by trigger input. AUTO(1s) : Cancelled after 1 second. AUTO(3s) : Cancelled after 3 seconds. AUTO(5s) : Cancelled after 5 seconds. OFF : Not cancelled. * When set to "AUTO" or "OFF", the displayed screen can be updated by trigger input during the FREEZE condi- tion. Sets the test pattern type output when the function set- ting switch No.1 is set to "ON". BAR : "BAR" pattern is output. RAMP : "RAMP" pattern is output. IMPULSE : "IMPULSE" pattern is output. Sets the level of the color signal bar output from the KY1030's [ANALOG OUT] connector. 0.7V: 0.7V test signal is output 0.57V: 0.57V test signal is output Resets all the set values of menus to the initial values. ੬ page E43, Resetting menu settings E40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

E40
Item
AE DISPLAY
FRZ DISPLAY
FRZ CANCEL
TEST PATTERN
LEVEL
When “BAR”/
“IMPULSE”
is selected
MENU RESET
SYSTEM SETTING screen
5. Menu screen settings (continued)
[ ] indicates the factory setting
Set Value
[OFF]
ON
[ON]
OFF
[MANUAL]
AUTO (1s)
AUTO (3s)
AUTO (5s)
OFF
[BAR]
RAMP
IMPULSE
[0.7V]
0.57V
Contents
Used to set whether the ALC, EEI and IRIS values are
displayed on the analog output screen.
OFF:
No on-screen-display
ON:
On-screen-display
Used to set whether the “FREEZE” indicator is shown on
the screen at the time of trigger input.
ON:
Displayed
OFF:
Not displayed
Sets the method for canceling the FREEZE when the
monitor screen is in FREEZE condition when connection
is made through digital output.
MANUAL
:
Cancelled by trigger input.
AUTO(1s) :
Cancelled after 1 second.
AUTO(3s) :
Cancelled after 3 seconds.
AUTO(5s) :
Cancelled after 5 seconds.
OFF
:
Not cancelled.
* When set to “AUTO” or “OFF”, the displayed screen can
be updated by trigger input during the FREEZE condi-
tion.
Sets the test pattern type output when the function set-
ting switch No.1 <TEST PATTERN> is set to “ON”.
BAR
:
“BAR” pattern is output.
RAMP
:
“RAMP” pattern is output.
IMPULSE :
“IMPULSE” pattern is output.
Sets the level of the color signal bar output from the KY-
1030’s [ANALOG OUT] connector.
0.7V:
0.7V test signal is output
0.57V:
0.57V test signal is output
Resets all the set values of menus to the initial values.
±
page E43, Resetting menu settings