JVC VN-E4U API Guide - Page 62

Acquiring Log, Motion Detect 2 total 2 times

Page 62 highlights

5. API for Acquiring/Changing Parameters of VN-E4 _ 5.15. Acquiring Status Acquiring Log Format Response /api/param?system.log Return the following information. These information will be initialized upon turning off the power of VN-E4. Response examples on the number of seconds after startup, alarm log information, motion detect log, list of clients currently acquiring alarm, clients currently sending audio data, and clients currently using passthrough. system.log=&200 OK system alive time: 2142sec Alarm Detect 1 ( total 2 times ) 2005/07/01 11:26:30 ( make ) 2005/07/01 11:26:29 ( break ) Alarm Detect 2 ( total 2 times ) 2005/07/01 11:26:30 ( make ) 2005/07/01 11:26:29 ( break ) Alarm Detect 3 ( total 2 times ) 2005/07/01 11:26:30 ( make ) 2005/07/01 11:26:29 ( break ) Alarm Detect 4 ( total 2 times ) 2005/07/01 11:26:30 ( make ) 2005/07/01 11:26:29 ( break ) Motion Detect 1 ( total 2 times ) 2005/07/01 11:26:30 2005/07/01 11:26:29 Motion Detect 2 ( total 2 times) 2005/07/01 11:26:30 2005/07/01 11:26:29 Motion Detect 3 ( total 2 times ) 2005/07/01 11:26:30 2005/07/01 11:26:29 Motion Detect 4 ( total 2 times ) 2005/07/01 11:26:30 2005/07/01 11:26:29 Alarm Monitor ( total 2 clients )

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

62
5. API for Acquiring/Changing Parameters of VN-E4 _
5.15. Acquiring Status
Acquiring Log
Format
/api/param?system.log
Response
Return the following information. These information will be initialized upon turning off the power of VN-E4.
Response examples on the number of seconds after startup, alarm log information, motion detect log, list of
clients currently acquiring alarm, clients currently sending audio data, and clients currently using pass-
through.
Interpretation
Acquire the VN-E4 log.
Allowed user
admin
system.log=&200 OK
system alive time: 2142sec
<----- No. of seconds after startup
Alarm Detect 1 ( total 2 times )
<----- Alarm input 1ch
(Blank in the case of 0 times)
2005/07/01 11:26:30 ( make )
<----- Up to the latest 10 line
2005/07/01 11:26:29 ( break )
<----- Up to the latest 10 line
Alarm Detect 2 ( total 2 times )
2005/07/01 11:26:30 ( make )
2005/07/01 11:26:29 ( break )
Alarm Detect 3 ( total 2 times )
2005/07/01 11:26:30 ( make )
2005/07/01 11:26:29 ( break )
Alarm Detect 4 ( total 2 times )
2005/07/01 11:26:30 ( make )
2005/07/01 11:26:29 ( break )
Motion Detect 1 ( total 2 times )
<----- Motion detect 1ch
(Blank in the case of 0 times)
2005/07/01 11:26:30
<----- Up to the latest 10 lines
2005/07/01 11:26:29
<----- Up to the latest 10 lines
Motion Detect 2 ( total 2 times)
2005/07/01 11:26:30
2005/07/01 11:26:29
Motion Detect 3 ( total 2 times )
2005/07/01 11:26:30
2005/07/01 11:26:29
Motion Detect 4 ( total 2 times )
2005/07/01 11:26:30
2005/07/01 11:26:29
Alarm Monitor ( total 2 clients )
<----- Clients currently acquiring alarm
(Blank in the case of 0 clients)
2005/07/01 11:26:30 ( 136.198.34.14 )
<----- Up to 4
2005/07/01 11:26:29 ( 10.0.0.1 )
Serial Passthrough ( total 2 clients )
<----- Clients currently using pass-through
(Blank in the case of 0 clients)
2005/07/01 11:26:30 ( 1 136.198.34.14 )
<----- Serial port no. and client's IP address
2005/07/01 11:26:29 ( 2 10.0.0.1 )
<----- Up to 2
Audio Client ( total 1 clients )
<----- Clients currently sending audio data to E4
(Blank in the case of 0 clients)
2005/07/01 11:26:30 ( 136.198.34.14 )
<----- Up to 1