JVC VN-X235U Instruction Manual - Page 13

Connecting the Alarm Input/Output Cable, Alarm Input, Input Requirements

Page 13 highlights

Connecting the Alarm Input/Output Cable Alarm Input Connect the cable to sensors such as infrared sensors, door sensors, metal sensors and manual switches. Ⅵ Input Requirements ● Non-voltage relay NPN open collector input ● Polarity of input detection can be selected using a software ● Make/break (500 ms and above) ● Circuit current of 1 mA during low-level input ● Applied voltage of 3.3 V during high-level input This unit DC3.3 V R Input 1 or Input 2 OUT Sensor example (1) VCC R 3.3 V 1 mA GND GND (Alarm input equivalent circuit) Sensor example (2) Relay switch, etc. OUT GND Alarm output Connect to alarm devices such as alarm, indicator, light or buzzer. Ⅵ Output Requirements ● NPN open collector output equivalent (Refer to the INSTRUCTIONS (Setting) on procedures to set the output logic. ) ● Allowable applied voltage: DC 12 V and below ● Allowable inflow current: 50 mA ● Momentary (100 ms to 5000 ms) output (Refer to [INSTRUCTIONS (Setting)] for procedures to set the time. ) This unit Output 1 or Output 2 Alarm device (example) DC 12 V IN R GND (Alarm output equivalent circuit) GND Note: ● Connect the GND cable of the camera to the GND terminal of the alarm device. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

13
Alarm Input
Connect the cable to sensors such as infrared
sensors, door sensors, metal sensors and
manual switches.
±
Input Requirements
Non-voltage relay NPN open collector input
Polarity of input detection can be selected
using a software
Make/break (500 ms and above)
Circuit current of 1 mA during low-level input
Applied voltage of 3.3 V during high-level
input
Alarm output
Connect to alarm devices such as alarm,
indicator, light or buzzer.
±
Output Requirements
NPN open collector output equivalent (Refer
to the INSTRUCTIONS (Setting) on
procedures to set the output logic. )
Allowable applied voltage: DC 12 V and
below
Allowable inflow current: 50 mA
Momentary (100 ms to 5000 ms) output
(Refer to [INSTRUCTIONS (Setting)] for
procedures to set the time. )
Note:
Connect the GND cable of the camera to the
GND terminal of the alarm device.
Connecting the Alarm
Input/Output Cable
DC
3
.
3
V
R
3
.
3
V
1 mA
VCC
OUT
GND
GND
OUT
R
GND
(Alarm input equivalent
circuit)
Input 1 or
Input 2
This unit
Sensor example
(1)
Sensor example
(2)
Relay switch, etc.
IN
R
DC 12 V
GND
GND
Alarm device
(example)
This unit
(Alarm output equivalent
circuit)
Output 1 or
Output 2