PERFORMANCE DATA SHEET Water Filtration System Model P9WB2L/EDR2RXD1 Capacity 200 Gallons (757 Liters) This system has been tested by an independent laboratory according to NSF/ANSI Standards 42, 53, 401, and CSA B483.1 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42, 53, 401, and CSA B483.1. Substance Reduction Aesthetic Effects Influent Challenge Concentration Maximum Permissible Average % Reduction Product Water Concentration Chlorine Taste/Odor Particulate 2.0 mg/L ± 10% At least 10,000 50% reduction 85% reduction Class I* particles/mL 97.2% 99.5% Contaminant Reduction Lead: @ pH 6.5 / @ pH 8.5 Benzene P-Dichlorobenzene Carbofuran Toxaphene Atrazine Asbestos Live Cysts† Turbidity Lindane Tetrachloroethylene O-Dichlorobenzene Ethylbenzene 1,2,4-Trichlorobenzene 2,4 - D Styrene Toluene Endrin Atenolol Trimethoprim Linuron Estrone Nonylphenol Carbamazepine Phenytoin Naproxen Bisphenol A Influent Challenge Concentration 0.15 mg/L ± 10% 0.015 mg/L ± 10% 0.225 mg/L ± 10% 0.08 mg/L ± 10% 0.015 ± 10% 0.009 mg/L ± 10% 107to 108fibers/L†† 50,000/L min. 11 NTU ± 10% 0.002 ± 10% 0.015 mg/L ± 10% 1.8 mg/L ± 10% 2.1 mg/L ± 10% 0.210 mg/L ± 10% 0.210 mg/L ± 10% 2.0 mg/L ± 10% 3.0 mg/L ± 10% 0.006 mg/L ± 10% 200 ± 20% 140 ± 20% 140 ± 20% 140 ± 20% 1400 ± 20% 1400 ± 20% 200 ± 20% 140 ± 20% 2000 ± 20% Maximum Permissible Product Water Concentration 0.010 mg/L 0.005 mg/L 0.075 mg/L 0.040 mg/L 0.003 mg/L 0.003 mg/L 99% 99.95% 0.5 NTU 0.0002 mg/L 0.015 mg/L ± 10% 0.60 mg/L 0.70 mg/L 0.07 mg/L 0.07 mg/L 0.1 mg/L 1.0 mg/L 0.002 mg/L 30 ng/L 20 ng/L 20 ng/L 20 ng/L 200 ng/L 200 ng/L 30 ng/L 20 ng/L 300 ng/L Average % Reduction >99.3% / 98.6% 96.0% >99.8% 91.9% 93.3% 92.4% >99% >99.99% 99.0% 98.9% >96.6% 99.9% 99.4% >99.8% 93.8% 99.8% 87.9% >96.6% >95.9% >96.9% >96.4% >97.0% >97.4% >97.9% 93.8% 96.1% >99.2% Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.6 gpm (2.27 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters). The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants." Emerging compounds/ incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/ perception of drinking water quality. 04-Jan-2021 11:49:29 EST | RELEASED 27 In some European factories the letter "W" of the part code mentioned herein will be automatically replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")
![](/manual_guide/products/jennair-jffcc72eh-owners-manual-8439d2f/27.png)