Page 3 highlights

Tools and Parts Gather the required tools and parts necessary for correct Propane gas conversion. Tools needed ■■ Flat-blade screwdriver ■■ 3/32" (#0 [2.0 mm]) flat-blade screwdriver (screwdriver shaft must be a minimum of 21/2" [6.4 cm] long) ■■ Adjustable wrench ■■ 7.0 mm nut driver ■■ 7.0 mm wrench Parts supplied ■■ Propane gas orifice spud (W11027216) High Altitude Conversion To convert the cooktop for elevations above 6,560 ft (1999.5 m), order a High Altitude Conversion Kit. ■■ Part Number W11035431: Propane gas high altitude ■■ Part Number W11035432: Natural gas high altitude To order, see the "Assistance or Service" section of the Use and Care Guide. IMPORTANT: Gas conversions from Natural gas to Propane gas must be done by a qualified installer. Before proceeding with conversion, shut off the gas supply to the cooktop prior to disconnecting the electrical power. WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer's instructions supplied with this kit. WARNING Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to propane, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. Convert from Natural Gas to Propane Gas 1. Turn manual shut-off valve to the closed position. B A C A. To cooktop B. Shut-off valve (closed position) C. Gas supply line 2. Unplug cooktop or disconnect power. To Convert Gas Pressure Regulator B A C D A. Access cap B. Rear of cooktop C. Gas pressure regulator D. Gas flow 3. Determine the type of regulator you have: Style 1: The cap has a slot and "NAT" printed on it. Remove access cap by using a flat-blade screwdriver or coin, turning the access cap counterclockwise. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

3
Tools and Parts
Gather the required tools and parts necessary for correct
Propane gas conversion.
Tools needed
Flat-blade screwdriver
3/32" (#0 [2.0 mm]) flat-blade screwdriver (screwdriver shaft
must be a minimum of 2
1
/
2
" [6.4 cm] long)
Adjustable wrench
7.0 mm nut driver
7.0 mm wrench
Parts supplied
Propane gas orifice spud (W11027216)
High Altitude Conversion
To convert the cooktop for elevations above 6,560 ft (1999.5 m),
order a High Altitude Conversion Kit.
Part Number W11035431: Propane gas high altitude
Part Number W11035432: Natural gas high altitude
To order, see the “Assistance or Service” section of the Use and
Care Guide.
IMPORTANT:
Gas conversions from Natural gas to Propane gas
must be done by a qualified installer. Before proceeding with
conversion, shut off the gas supply to the cooktop prior to
disconnecting the electrical power.
Convert from Natural Gas
to Propane Gas
1.
Turn manual shut-off valve to the closed position.
2.
Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
3.
Determine the type of regulator you have:
Style 1:
The cap has a slot and “NAT” printed on it.
Remove access cap by using a flat-blade screwdriver
or coin, turning the access cap counterclockwise.
WARNING
This conversion kit shall be installed by a
qualified service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements of
the authority having jurisdiction. If the
information in these instructions is not
followed exactly, a fire, explosion or
production of carbon monoxide may
result causing property damage, personal
injury or loss of life. The qualified service
agency is responsible for the proper
installation of this kit. The installation is
not proper and complete until the
operation of the converted appliance is
checked as specified in the
manufacturer's instructions supplied with
this kit.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
A. To cooktop
B. Shut-off valve (closed position)
C. Gas supply line
A
B
C
D
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Gas flow