Jenn-Air JGD8130ADS Dimension Guide - Page 2

Fax on Demand 775 833-3600 - 30 gas cooktop

Page 2 highlights

www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600 Page 2 Additional Information: • Electric supply: 120 VAC, 60Hz. 15 amp grounded circuit is required, Power cord is NOT supplied. • Duct requirements: See page 3 for ducting information and below for location. • Under counter access must be provided to remove and empty grease container(s). • Gas requirements : The Appliance pressure regulator supplied with this appliance is pre-set and fixed for correct outlet pressure: 5" W.C. this model is equipped for use with natural gas; 10" W.C. when converting to LP. The maximum inlet gas supply pressure for the regulator is 14" W.C. The inlet test pressure for checking the regulator must be at least 6" W.C if equipped for natural gas; 11" W.C. if converted to LP gas. • An individual gas shut-off valve must be used. This Data Sheet Includes Information On Jenn-Air • Product Model Number (s): • 30" Convertible Cooktops: JGD8130ADW, JGD8130ADS and JGD8130ADB Duct locations (not to scale) 7 9/16" 13" 9 3/8" Top of counter to centerline of back duct location: 13" Left edge of cutout to centerline of back and bottom duct locations: 9 3/8" Front edge of cutout to centerline of bottom duct location: 7 9/16" Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002. 149 • NEVER reuse Data Sheets. Data Sheets are subject to change without notice. Dimension Express is a FREE service bureau and is updated daily, it makes far more sense to spend the time necessary to request new Data Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets. • Call Dimension Express if you have any questions at (775) 833-3633 • • Always refer to a current Code at a Glance or manufacturer directory • • Data Sheet codes change on the first of odd numbered months at 12:01am • BN182.34 • A321B149C150 • • 032603 • 95657 • 67301

  • 1
  • 2
  • 3

• Electric supply: 120 VAC, 60Hz.
15 amp grounded circuit is required,
Power cord is NOT supplied.
• Duct requirements: See page 3 for ducting information and below for
location.
• Under counter access
must be provided to remove and empty
grease container(s).
• Gas requirements : The Appliance pressure regulator supplied with
this appliance is pre-set and fixed for correct outlet pressure: 5" W.C.
this model is equipped for use with natural gas; 10" W.C. when
converting to LP.
The maximum inlet gas supply pressure for the
regulator is 14" W.C.
The inlet test pressure for checking the regulator
must be at least 6" W.C if equipped for natural gas;
11" W.C. if
converted to
LP gas.
• An individual gas shut-off valve must be used.
13"
Duct locations
(not to scale)
7 9/16"
9 3/8"
Top of counter to centerline of back duct location: 13"
Left edge of cutout to centerline of back and bottom duct locations: 9 3/8"
Front edge of cutout to centerline of bottom duct location: 7 9/16"
Additional Information:
Subject to change without notice.
This system is designed to be updated daily if necessary.
Dimension Express is not responsible for use of superseded, voided, or
outdated data sheets.
Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright ©
Dimension Express, 2002.
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
• NEVER reuse Data Sheets.
Data Sheets are subject to change without
• Call Dimension Express if you have any questions at (775) 833-3633 •
notice.
Dimension Express is a FREE service bureau and is updated daily,
• Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data
• Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
30"
Convertible Cooktops:
JGD8130ADW, JGD8130ADS and JGD8130ADB
Product Model Number (s):
This Data Sheet Includes Information On
BN182.34 • A321B149C150 •
• 032603 • 95657 • 67301
149
Page 2