Jenn-Air JIC4730H Installation Instructions - Page 5
Warning
View all Jenn-Air JIC4730H manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
A D B C F Electrical Requirements WARNING E Cooktop E Foam Strip (optional) A. Recessed area length 213/16" (53.8 cm) B. Cutout length 203/8" (51.8 cm) C. See the "Flush Install Dimension" table. D. See the "Flush Install Dimension" table. E. Recessed area depth 11/64" (4.3 mm) F. Recessed area radius 5/64" (2.0 mm) maximum Flush Install Dimension Table Units Recessed Area Cutout Width (D) Width (C) One 15" (38.1 cm) unit Two 15" (38.1 cm) units Three 15" (38.1 cm) units Four 15" (38.1 cm) units 24" (61.0 cm) cooktop 151/8" (38.4 cm) 301/8" (76.5 cm) 451/8" (114.6 cm) 601/8" (152.7 cm) 241/8" (61.3 cm) 24" (61.0 cm) and one 15" (38.1 cm) cooktop 24" (61.0 cm) and two 15" (38.1 cm) cooktop 30" (76.2 cm) cooktop 391/8" (99.4 cm) 54 1/8" (137.5 cm) 301/8" (76.5 cm) 30" (76.2 cm) cooktop and one 15" (38.1 cm) unit 30" (76.2 cm) cooktop and two 15" (38.1 cm) units 36" (91.4 cm) cooktop 36" (91.4 cm) cooktop and one 15" (38.1 cm) unit 451/8" (114.6 cm) 601/8" (152.7 cm) 361/8" (91.8 cm) 511/8" (129.9 cm) 143/8" (36.5 cm) 293/8" (74.6 cm) 447/16" (112.9 cm) 597/16" (151.0 cm) 233/8" (59.4 cm) 383/16" (97.0 cm) 533/8" (135.6 cm) 293/8" (74.6 cm) 443/16" (112.2 cm) 593/8" (150.8 cm) 353/8" (89.9 cm) 503/16" (127.5 cm) IMPORTANT: If multiple units are installed side by side, the mounting bridge kit W11031680 is needed for proper installation. Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper wire. Electrically ground cooktop. Failure to follow these instructions can result in death, fire, or electrical shock. If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes. Check with a qualified electrical installer if you are not sure the cooktop is properly grounded. Make sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all local codes and ordinances. A copy of the above code standards can be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575 5