DETAILED PLANNING DIMENSIONS 3 of 8 JENNAIR® SMALL STEAM OVEN - STANDARD INSTALLATION JJW6024HM - 237⁄16" X 185⁄16" X 203⁄8" (Depth Without Handle) JJW6024HL - 237⁄16" X 185⁄16" X 203⁄8" (Depth Without Handle) OPENING/CLEARANCE DIMENSIONS A D B C* E MODEL # JJW6024HM JJW6024HL in cm A Width of cabinet (min.) 235⁄8 60 B Width of cutout 22 55.8 C* Height of cutout (recommended) 1713⁄16 45.3 D Top of cutout to bottom of upper cabinet door (min.) 1/2 1.2 E Bottom of cutout to top of lower cabinet door (min.) 1/2 1.2 F Depth of cutout (min.) 199⁄16 49.7 G Top of cutout to underside of countertop (min.) 1/2 1.2 H Bottom of cutout to floor (min.) 1/2 1.2 e Recommended junction box location *Will fit cutout height from 173⁄4" (45 cm) to 1715⁄16" (45.6 cm) e e F FRONT VIEW A e B C* SIDE VIEW G e ELECTRICAL REQUIREMENTS 120 V, 15 A fused, grounded circuit is required. A dedicated circuit is required. The length of conduit provided is for serviceability. Do not cut the conduit. The junction box should be located 3" (7.6 cm) maximum below the support surface. Drill a 1" (2.5 cm) minimum diameter hole in the right rear or left rear corner of the support surface for access to the junction box. NOTE: For under counter installation, the junction box should be located in the adjacent right or left cabinet. Drill a 1" (2.5 cm) minimum diameter hole in an upper corner of the side wall for access to the junction box. Power Supply Location g gH UNDER COUNTER INSTALLATION (without cooktop installed above) BACK VIEW IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation Guide before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All JennAir® appliances are appropriately UL, CUL or CSA approved.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

DETAILED PLANNING DIMENSIONS
3 of 8
IMPORTANT:
Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information.
Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All JennAir
®
appliances are appropriately UL, CUL or CSA approved.
JENNAIR
®
SMALL STEAM OVEN - STANDARD INSTALLATION
JJW6024HM – 23
7
16
" X 18
5
16
" X 20
3
8
" (Depth Without Handle)
JJW6024HL – 23
7
16
" X 18
5
16
" X 20
3
8
" (Depth Without Handle)
OPENING/CLEARANCE DIMENSIONS
A
D
B
C*
E
e
F
e
FRONT VIEW
SIDE VIEW
A
G
H
e
e
g
g
C*
B
Power Supply
Location
UNDER COUNTER INSTALLATION
(without cooktop installed above)
BACK VIEW
MODEL
#
JJW6024HM
JJW6024HL
in
cm
A
Width of cabinet (min.)
23
5
8
60
B
Width of cutout
22
55.8
C*
Height of cutout
(recommended)
17
13
16
45.3
D
Top of cutout to bottom of
upper cabinet door (min.)
1/2
1.2
E
Bottom of cutout to top of
lower cabinet door (min.)
1/2
1.2
F
Depth of cutout (min.)
19
9
16
49.7
G
Top of cutout to underside
of countertop (min.)
1/2
1.2
H
Bottom of cutout to floor
(min.)
1/2
1.2
e
Recommended junction box location
*Will fit cutout height from 17
3
4
" (45 cm) to 17
15
16
" (45.6 cm)
ELECTRICAL REQUIREMENTS
120 V, 15 A fused, grounded circuit is required. A dedicated
circuit is required.
The length of conduit provided is for serviceability. Do not cut
the conduit. The junction box should be located 3" (7.6 cm)
maximum below the support surface. Drill a 1" (2.5 cm)
minimum diameter hole in the right rear or left rear corner of the
support surface for access to the junction box.
NOTE:
For under counter installation, the junction box should
be located in the adjacent right or left cabinet. Drill a 1" (2.5 cm)