Jenn-Air JJW6024HM Dimension Guide - Page 4

Jennair, Small Steam Oven - Flush Installation

Page 4 highlights

DETAILED PLANNING DIMENSIONS 4 of 8 JENNAIR® SMALL STEAM OVEN - FLUSH INSTALLATION JJW6024HM - 237⁄16" X 185⁄16" X 203⁄8" (Depth Without Handle) JJW6024HL - 237⁄16" X 185⁄16" X 203⁄8" (Depth Without Handle) OPENING/CLEARANCE DIMENSIONS 1/4" (0.6 cm) Top Cleat* A B C D 3/4" x 1" (1.9 x 2.5 cm) width x min. thickness Side Cleat* 3" x 1/2" (7.6 cm x 1.3 cm) or 3" x 5/16" (7.6 cm x 0.8 cm) without bottom trim Width x Height Spacer (entire depth of cutout) e e E FRONT VIEW SIDE VIEW 1/4" (0.6 cm) Top Cleat* e A e B C D 3/4" x 1" (1.9 x 2.5 cm) width x min. thickness Side Cleat* 3" x 1/2" (7.6 cm X 1.3 cm) or 3" x 5/16" (7.6 cm x 0.8 cm) without bottom trim Width X Height Spacer (entire depth of cutout) MODEL # JJW6024HM JJW6024HL in cm A Width of flush inset cutout (min.) 2311⁄16 60.2 B Width of opening (min.) 22 55.9 C Height of flush inset cutout (min.) 189⁄16 47.2 D Height of opening (min.) 183⁄8 46.6 E Depth of cutout (min.) 203⁄8 51.8 e Recommended junction box location ELECTRICAL REQUIREMENTS 120 V, 15 A fused, grounded circuit is required. A dedicated circuit is required. The length of conduit provided is for serviceability. Do not cut the conduit. The junction box should be located 3" (7.6 cm) maximum below the support surface. Drill a 1" (3.4 cm) minimum diameter hole in the right rear or left rear corner of the support surface for access to the junction box. NOTE: For under counter installation, the junction box should be located in the adjacent right or left cabinet. Drill a 1" (2.5 cm) minimum diameter hole in an upper corner of the side wall for access to the junction box. FLUSH INSTALLATION REQUIREMENTS A 207⁄16" (51.8 cm) minimum cutout depth is required. These dimensions will result in a 1/8" (0.3 cm) reveal on the top, a 1/8" (0.3 cm) reveal on the sides and a 1/8" (0.3 cm) reveal on the bottom of the wall oven. The front face of the cleats and spacers will be visible and should be treated as a finished surface. CABINET REQUIREMENTS NOTE: When using under counter installation, check cabinet manufacturer's specifications to verify fit. Power Supply Location E Side Cleat* Side Cleat* JJW6024HM: 13/16" (20.5 mm) JJW6024HL: 7/8" (21.3 mm) UNDER COUNTER INSTALLATION (without cooktop installed above) TOP VIEW *Cleats and spacers must be recessed 13/16" (2.1 cm) from the front of the cabinet. IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation Guide before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All JennAir® appliances are appropriately UL, CUL or CSA approved. BACK VIEW W11318374C Installation Instructions: W11260095

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

DETAILED PLANNING DIMENSIONS
4 of 8
W11318374C
Installation Instructions: W11260095
JENNAIR
®
SMALL STEAM OVEN - FLUSH INSTALLATION
JJW6024HM – 23
7
16
" X 18
5
16
" X 20
3
8
" (Depth Without Handle)
JJW6024HL – 23
7
16
" X 18
5
16
" X 20
3
8
" (Depth Without Handle)
IMPORTANT:
Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information.
Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All JennAir
®
appliances are appropriately UL, CUL or CSA approved.
OPENING/CLEARANCE DIMENSIONS
A
1/4
"
(0.6 cm)
Top Cleat*
3/4
" x 1"
(1.9 x 2.5 cm)
width x min. thickness
Side Cleat*
3
"
x 1/2
"
(7.6 cm x 1.3 cm) or
3" x 5/16" (7.6 cm x 0.8 cm)
without bottom trim
Width x Height
Spacer (entire depth
of cutout)
B
C
D
e
e
E
FRONT VIEW
e
e
Spacer (entire
depth of cutout)
1/4
"
(0.6 cm)
Top Cleat*
3/4
" x 1"
(1.9 x 2.5 cm)
width x min. thickness
Side Cleat*
3
"
x 1/2
"
(7.6 cm X 1.3 cm) or
3" x 5/16" (7.6 cm x 0.8 cm)
without bottom trim
Width X Height
A
B
C
D
JJW6024HM: 13/16" (20.5 mm)
JJW6024HL: 7/8" (21.3 mm)
Side Cleat*
Side Cleat*
E
Power Supply
Location
BACK VIEW
TOP VIEW
MODEL
#
JJW6024HM
JJW6024HL
in
cm
A
Width of flush inset cutout (min.)
23
11
16
60.2
B
Width of opening (min.)
22
55.9
C
Height of flush inset cutout (min.)
18
9
16
47.2
D
Height of opening (min.)
18
3
8
46.6
E
Depth of cutout (min.)
20
3
8
51.8
e
Recommended junction box location
ELECTRICAL REQUIREMENTS
120 V, 15 A fused, grounded circuit is required. A dedicated
circuit is required.
The length of conduit provided is for serviceability. Do not cut the
conduit. The junction box should be located 3" (7.6 cm) maximum
below the support surface. Drill a 1" (3.4 cm) minimum diameter
hole in the right rear or left rear corner of the support surface for
access to the junction box.
NOTE:
For under counter installation, the junction box should
be located in the adjacent right or left cabinet. Drill a 1" (2.5 cm)
minimum diameter hole in an upper corner of the side wall for
access to the junction box.
FLUSH INSTALLATION REQUIREMENTS
A 20
7
16
" (51.8 cm) minimum cutout depth is required. These
dimensions will result in a 1/8" (0.3 cm) reveal on the top, a
1/8" (0.3 cm) reveal on the sides and a 1/8" (0.3 cm) reveal on the
bottom of the wall oven.
The front face of the cleats and spacers will be visible and should
be treated as a finished surface.
CABINET REQUIREMENTS
NOTE:
When using under counter installation, check cabinet
manufacturer’s specifications to verify fit.
SIDE VIEW
*Cleats and spacers must be recessed 13/16" (2.1 cm) from the front of the cabinet.
UNDER COUNTER INSTALLATION
(without cooktop installed above)