Jenn-Air JXW8030WS Installation Instruction - Page 7

Install Range Hood, Connect Vent System

Page 7 highlights

6. Select a mounting height between a minimum of 24" (61.0 cm) for an electric cooking surface, a minimum of 27" (68.6 cm) for a gas cooking surface, and a suggested maximum of 36" (91.4 cm) above the range to the bottom of the hood. Mark a reference line on the wall. 7. Tape template in place, aligning the template centerline and bottom of template with hood bottom line and with the centerline marked on the wall. A DRILL2 (TW O)3/16"PILOT HOLES THROUGH STUDS OR REAR W ALLSUPPORT Vertical Centerline REAR W ALL M OUNTING TEM PLATE HorizontalLine CL ALIGN BOTTOM EDGE W ITH PENCILLINE INDICATING BOTTOM OFTHE HOOD Installation Height B C A. Centerline B. Fastener locations C. Mounting height reference (hood bottom line) 8. Mark centers of the fastener locations through the template to the wall. IMPORTANT: All screws must be installed into wood. If there is no wood to screw into, additional wall framing supports may be required. Remove the template. 9. Drill 4.8 mm) pilot holes at all locations where screws are being installed into wood. 10. Install the 2 - 5 x 45 mm mounting screws. Leave a ¹⁄₄" (6.4 mm) gap between the wall and the back of the screw head to slide range hood into place. ¹⁄₄" (6.4 mm) Vent Cover Bracket Installation 11. Attach vent cover bracket to wall flush to the ceiling using 2 - 5 x 45 mm screws. Complete Preparation 1. Determine and make all necessary cuts in the wall for the vent system. Install the vent system before installing the hood. See "Venting Requirements" section. 2. Determine the required height for the home power supply cable and drill a 1¼" (3.2 cm) hole at this location. 3. Run the home power supply cable according to the National Electrical Code or CSA Standards and local codes and ordinances. There must be enough ½" conduit and wires from the fused disconnect (or circuit breaker) box to make the connection in the hood's electrical terminal box. NOTE: Do not reconnect power until installation is complete. 4. Use caulk to seal all openings. Install Range Hood 1. Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of hood. A B C A. Mounting screws B. Mounting slots C. Lower mounting screws and washers 2. Remove the grease filter. See "Range Hood Care" section. 3. Level the range hood and tighten upper mounting screws. 4. Install 2 - 5 x 45 mm lower mounting screws and 2 - D6.4 x 18 mm washers and tighten. Connect Vent System 1. Install transition on top of hood (if removed for shipping) with 4 - 3.5 x 9.5 mm sheet metal screws. B A B C A. Ceiling B. Wall C. Centerline A B A. Vent transition B. 3.5 x 9.5 mm screw 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

7
6.
Select a mounting height between a minimum of
24" (61.0 cm) for an electric cooking surface, a minimum
of 27" (68.6 cm) for a gas cooking surface, and a suggested
maximum of 36" (91.4 cm) above the range to the bottom
of the hood. Mark a reference line on the wall.
7.
Tape template in place, aligning the template centerline and
bottom of template with hood bottom line and with the
centerline marked on the wall.
8.
Mark centers of the fastener locations through the template
to the wall.
IMPORTANT:
All screws must be installed into wood. If there
is no wood to screw into, additional wall framing supports
may be required.
Remove the template.
9.
Drill
³⁄₁₆
" (4.8 mm) pilot holes at all locations where screws are
being installed into wood.
10.
Install the 2 - 5 x 45 mm mounting screws. Leave a
¹⁄₄
" (6.4 mm) gap between the wall and the back of the
screw head to slide range hood into place.
Vent Cover Bracket Installation
11.
Attach vent cover bracket to wall flush to the ceiling using
2 - 5 x 45 mm screws.
Complete Preparation
1.
Determine and make all necessary cuts in the wall for the vent
system. Install the vent system before installing the hood. See
“Venting Requirements” section.
2.
Determine the required height for the home power supply
cable and drill a 1¼" (3.2 cm) hole at this location.
3.
Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough ½" conduit and wires from
the fused disconnect (or circuit breaker) box to make the
connection in the hood’s electrical terminal box.
NOTE:
Do not reconnect power until installation is complete.
4.
Use caulk to seal all openings.
Install Range Hood
1.
Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
2.
Remove the grease filter. See “Range Hood Care” section.
3.
Level the range hood and tighten upper mounting screws.
4.
Install 2 - 5 x 45 mm lower mounting screws and 2 - D6.4 x
18 mm washers and tighten.
Connect Vent System
1.
Install transition on top of hood (if removed for shipping) with
4 - 3.5 x 9.5 mm sheet metal screws.
A. Centerline
B. Fastener locations
C. Mounting height reference
(hood bottom line)
A. Ceiling
B. Wall
C. Centerline
Vertical Centerline
C
L
L
L
A
W
R
A
E
R
E
T
A
L
P
M
E
T
G
N
I
T
N
U
O
M
E
G
D
E
M
O
T
T
O
B
N
G
I
L
A
E
N
I
L
L
I
C
N
E
P
H
T
I
W
M
O
T
T
O
B
G
N
I
T
A
C
I
D
N
I
D
O
O
H
E
H
T
F
O
t
h
g
i
e
H
n
o
i
t
a
l
l
a
t
s
n
I
T
R
O
P
P
U
S
L
L
A
W
R
A
E
R
R
O
S
D
U
T
S
H
G
U
O
R
H
T
S
E
L
O
H
T
O
L
I
P
"
6
1
/
3
)
O
W
T
(
2
L
L
I
R
D
e
n
i
L
l
a
t
n
o
z
i
r
o
H
A
C
B
¹⁄₄
"
(6.4 mm)
A
C
B
A. Mounting screws
B. Mounting slots
C. Lower mounting screws and washers
A. Vent transition
B. 3.5 x 9.5 mm screw
A
B
C
A
B
B