POWER FAILURE When power to the freezer is restored after the occurrence of a power failure, the "Power Loss" LED will be illuminated. If the internal temperature of the freezer has risen to a temperature greater than 23°F (-5°C), the "Hi Temp" display indicator will also be illuminated and there will be an audible beep every five seconds. Press the Alarm Reset button to turn the audible alarm (beep) off. If this condition persists, the "Duration" indicator will also be illuminated and the display will show how many hours (up to a period of 48) the internal temperature has been above 23°F (-5°C). Food quality is considered to be impaired at temperatures greater than 23°F (-5°C). It is left to the user's discretion to decide how to best manage the contents within the freezer. Door Ajar Power Loss Quick Freeze H01d For_fC Temp Display Alarm Reset f ALARM FUNCTION TABLE Except during power loss, the alarm indicators illuminate whenever there is an alarm status. Display Status Cabinet temperature setting is displayed Alternating "E' and "7", "8" or "9" every half second Control panel beeps every 5 seconds. "Door Ajar" LED is lit. Control panel beeps every 5 seconds. "Hi Temp" LED is lit. "Power Loss" LED is illuminated. Function Normal operation Operational error Door Ajar Freezer temperature too high. A power failure occurred. Response None Contact service technician. Close door. Press Alarm Reset to mute audible alarm (beep). Contact service technician. Press Alarm Reset to mute audible alarm (beep). Press Alarm Reset button. Display off. Power failure Reconnect power supply. Figure 7 SYSTEM ERROR ALARMS If "E7", "E8", or "E9" are shown on the display every half second and the control panel beeps every five seconds, call service repair to correct the problem. Press the Alarm Reset button to turn the audible alarm (beep) off. Until changes are made, freezer will continue to run.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

POWER
FAILURE
When power to the freezer is restored after the occur-
rence of a power failure, the "Power Loss" LED will be
illuminated.
If the internal temperature
of the freezer has risen to
a temperature
greater than 23°F (-5°C), the "Hi Temp"
display indicator will also be illuminated
and there will
be an audible beep every five seconds. Press the Alarm
Reset button to turn the audible alarm (beep) off.
If this condition
persists, the "Duration"
indicator will
also be illuminated
and the display will show how many
hours (up to a period of 48) the internal temperature
has
been above 23°F (-5°C). Food quality is considered
to be
impaired
at temperatures
greater than 23°F (-5°C). It is left
to the user's discretion
to decide how to best manage the
contents within the freezer.
Door
Ajar
Power
Loss
H01dFor_fC
Quick
Temp
Alarm
Freeze
Display
Reset
f
Figure 7
SYSTEM
ERROR ALARMS
If "E7", "E8", or "E9" are shown on the display every half
second and the control panel beeps every five seconds,
call service
repair to correct the problem. Press the Alarm
Reset button to turn the audible alarm (beep) off. Until
changes are made, freezer will continue
to run.
ALARM
FUNCTION
TABLE
Except during power loss, the alarm indicators
illuminate
whenever
there is an alarm status.
Display
Status
Cabinet
temperature
setting is
displayed
Alternating
"E'
and "7", "8" or "9"
every half second
Control panel
beeps every 5
seconds. "Door
Ajar" LED is lit.
Control panel
beeps every 5
seconds. "Hi
Temp" LED is lit.
Function
Normal operation
Operational
error
Door Ajar
Freezer
temperature
too
high.
Response
None
Contact service
technician.
Close door. Press
Alarm
Reset
to mute audible
alarm (beep).
Contact service
technician.
Press
Alarm
Reset
to mute audible
alarm (beep).
Press Alarm
Reset button.
"Power
A power failure
Loss" LED is
occurred.
illuminated.
Display off.
Power failure
Reconnect
power
supply.