Kenmore 75151 Owners Manual - Page 5

Installation, Requirements - manual

Page 5 highlights

INSTALLATION REQUIREMENTS Your air conditioner will install into standard double hung windows with actual clear opening widths of 29 to 41 inches (737mm to 1041mm) (FIG. 1) Lower sash must open sufficiently to allow a clear vertical opening of 18 inches (457mm). Side louvers and the rear of the air conditioner must have clear air space to allow enough airflow through the condenser for heat removal. The rear of the unit must be outdoors, not inside a building or garage. __J/- .... I/ ....i.'.. 29t"o_S4t" 18"min. _/ Sash ,. , Inner sillL [ _ wlnaow Offset ;"_.__;,; Sill '1 / "'-,I |i-;i- Exterior "" FIG 1 Interior wall "- .... " ELECTRICAL SERVICE Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on right side of cabinet). All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to make the necessary corrections. SAVE CARTON and this OWNER'S MANUAL for future reference. The carton is the best way to store unit during winter or when not in use. To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed: • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. • Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time. • Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. • Make sure air conditioner does not fall during installation. INSTALLATION HARDWARE B C DE F GH I JK L FIG. 2 ITEM A B C D E F G H I J K L M NAME OF PARTS SIDE CURTAIN SUPPORT BRACKET SILL BRACKET LOCK NUT SCREW: 25/64" SCREW: 13/16'' SCREW: 9/16" M-SCREW CARRIAGE BOLT FOAM SEAL FOAM STRIP WINDOW LOCKING BRACKET DRAIN PIPE Q'TY 2 2 2 4 11 7 5 2 2 1 1 1 1 REQUIRED TOOLS: • Tight Fitting gloves • Standard screwdriver • Phillips screwdriver • Pliers • Sharp knife • 3/8-inch open end wrench or adjustable wrench • 1/4-inch hex socket and ratchet • Tape measure • Electric drill • 1/4-inch drill bit -5-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

INSTALLATION
REQUIREMENTS
Your air conditioner
will install into standard
double
hung windows
with actual clear opening widths
of
29 to 41 inches (737mm to 1041mm)
(FIG. 1)
Lower sash must open sufficiently
to allow a clear
vertical opening
of 18 inches (457mm).
Side louvers
and the rear of the air conditioner
must have clear
air space to allow enough
airflow through
the
condenser
for heat removal.
The rear of the unit
must be outdoors,
not inside a building or garage.
__J/-
....
Sash
.......
i'
29"
to_S4t"
I/
18"min.
_/
,
.
,
Inner sillL
[_
wlnaow
,_" "_<
:>,_.--Offset
;"
_.__;,;
Sill
'1
/
"'-,I
|i-;i-
Exterior
""
FIG
1
Interior wall
"-
....
"
ELECTRICAL
SERVICE
Check your available electrical service. The power
supply available must be the same as that shown on
the unit nameplate (found on right side of cabinet).
All models are equipped
with a 3-prong
service plug
to provide proper service and safe positive
grounding.
Do not change
plug in any way. Do not
use an adapter
plug. If your present wall outlet does
not match your plug, call a qualified
electrician
to
make the necessary
corrections.
SAVE CARTON
and this OWNER'S
MANUAL
for
future reference.
The carton is the best way to store
unit during winter or when not in use.
To avoid risk of personal injury, property damage,
or product damage due to the weight of this
device and sharp edges that may be exposed:
• Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people
are needed to move and install the unit.
To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
• Carefully inspect location where air conditioner
will be installed. Be sure it will support the
weight of the unit over an extended period of
time.
• Handle air conditioner with care. Wear
protective gloves whenever lifting or carrying the
unit. AVOID the sharp metal fins of front and
rear coils.
• Make sure air conditioner does not fall during
installation.
INSTALLATION
HARDWARE
L
B
C
D
E
F
G
H
I
J
K
FIG.
2
ITEM
NAME OF PARTS
Q'TY
A
SIDE CURTAIN
2
B
SUPPORT
BRACKET
2
C
SILL BRACKET
2
D
LOCK NUT
4
E
SCREW:
25/64"
11
F
SCREW:
13/16
''
7
G
SCREW:
9/16"
5
H
M-SCREW
2
I
CARRIAGE
BOLT
2
J
FOAM SEAL
1
K
FOAM STRIP
1
L
WINDOW LOCKING BRACKET
1
M
DRAIN PIPE
1
REQUIRED
TOOLS:
• Tight Fitting gloves
• Standard
screwdriver
• Phillips screwdriver
• Pliers
• Sharp knife
• 3/8-inch open
end
wrench or adjustable wrench
• 1/4-inch hex socket and ratchet
• Tape measure
• Electric drill
• 1/4-inch drill bit
-5-