Gas Type, Burner, requirements

Page 6 highlights

An individual shutoff valve must be installed within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The shut off valve location should be easy to reach for opening and closing. E Explosion Hazard Use a new CSA International approved gas supply line. Install a shut=off valve. Securely tighten all gas connections. if connected to LP, have a qualified person make sure gas pressure does not exceed 13" (330 ram) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. Gas Type Natural Gas: This dryer is equipped for use with Natural gas. It is designcertified by CSA International for LP (propane or butane) gases with appropriate conversion. • Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your local Sears store or Sears Service Center. LP gas conversion: Conversion must be made by a qualified technician. No attempt shall be made to convert the dryer from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company. Gas supply line Must include 1/8" NPT minimum plugged tapping accessible for test gage connection, immediately upstream of the gas connection to the dryer (see illustration). 1/2" IPS or NPT pipe is recommended. 3/8" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit. If you are using Natural gas, do not use copper tubing. Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting. If your dryer has been converted to use LP gas, 3/8" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON e_ttape. • Must include a shutoff valve: 1-®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. 6 B A. 3/8" flexible gas connector B. 3/8" pipe to flare adapter fitting C. 1/8" NPT minimum plugged tapping D. 1/2" NPT gas supply line E. Gas shutoff valve Gas supply connection requirements Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking. Use only pipe-joint compound. Do not use TEFLON °t tape. This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24. Burner input requirements Elevations up to 10,000 ft (3,048 meters): • The design of this dryer is certified by CSA International for use at altitudes up to 10,000 ft (3,048 m) above sea level at the Btu rating indicated on the model/serial number plate. Burner input adjustments are not required when the dryer is operated up to this elevation. Elevations above 10,000 ft (3,048 meters): • When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation. Gas Supply Pressure Testing • The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than 1/2 psi. Dryer Gas Pipe • The gas pipe that comes out through the rear of your dryer has a 3/8" male pipe thread. 11/4" (32 rnm} + // A/ _--- 9¼" ---_ (235 mm) A. 3/8" NPT dryer pipe

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Explosion
Hazard
Use
a new
CSA International
approved
gas supply line.
Install
a
shut=off valve.
Securely
tighten
all
gas
connections.
if connected
to
LP, have
a qualified
person
make sure
gas pressure
does not
exceed
13"
(330
ram)
water
column.
Examples
of a qualified
person include:
licensed
heating personnel,
authorized
gas company
personnel,
and
authorized
service
personnel.
Failure
to
do so can result in death, explosion,
or fire.
Gas Type
Natural
Gas:
This dryer is equipped
for use with
Natural
gas. It is design-
certified
by CSA International
for LP (propane
or butane) gases
with appropriate
conversion.
Your dryer must have the correct
burner for the type of gas
in your home. Burner
information
is located
on the rating
plate in the door well of your dryer. If this information
does
not agree with the type of gas available,
contact
your local
Sears store or Sears Service
Center.
LP gas conversion:
Conversion
must be made
by
a
qualified
technician.
No attempt
shall be made to convert the dryer from the gas
specified
on the model/serial
rating
plate for use with a different
gas without
consulting
your gas company.
Gas supply
line
Must include 1/8"
NPT minimum
plugged
tapping
accessible
for test gage connection,
immediately
upstream
of the gas
connection
to the dryer (see illustration).
1/2"
IPS or NPT pipe is recommended.
3/8" approved
aluminum
or copper
tubing
is acceptable
for lengths under 20 ft (6.1 m) if local codes and gas
supplier
permit.
If you are using Natural gas, do not use copper
tubing.
Lengths
over 20 ft (6.1 m) should use larger tubing
and
a different
size adapter
fitting.
If your dryer has been converted
to use LP gas, 3/8" LP
compatible
copper tubing
can be used. If the total length
of the supply
line is more than 20 ft (6.1 m), use larger pipe.
NOTE:
Pipe-joint
compounds
that resist the action of
LP gas must be used. Do not use TEFLON e_ttape.
Must include a shutoff
valve:
An individual
shutoff
valve must be installed
within six (6) feet
(1.8 m) of the dryer
in accordance
with
the National
Fuel Gas
Code, ANSI Z223.1. The shut off valve location
should
be easy
to reach for opening and closing.
E
B
A. 3/8" flexible
gas connector
B. 3/8" pipe
to flare adapter
fitting
C. 1/8" NPT minimum
plugged
tapping
D. 1/2" NPT gas supply
line
E. Gas shutoff
valve
Gas supply
connection
requirements
Use an elbow and a 3/8" flare x 3/8"
NPT adapter
fitting
between
the flexible
gas connector
and the dryer gas pipe,
as needed to avoid
kinking.
Use only pipe-joint
compound.
Do not use TEFLON °t tape.
This dryer must be connected
to the gas supply
line with a
listed flexible gas connector
that complies with the standard
for connectors
for gas appliances,
ANSI Z21.24.
Burner
input
requirements
Elevations
up to 10,000 ft (3,048 meters):
The design of this dryer is certified
by CSA International
for
use at altitudes
up to 10,000 ft (3,048 m) above sea level at
the Btu rating indicated
on the model/serial
number
plate.
Burner
input adjustments
are not required when the dryer
is operated
up to this elevation.
Elevations
above
10,000
ft (3,048 meters):
When
installed
above
10,000 ft (3,048 m) a 4% reduction
of
the burner Btu rating shown
on the model/serial
number
plate
is required for each 1,000 ft (305 m) increase
in elevation.
Gas Supply Pressure Testing
The dryer must be disconnected
from the gas supply
piping
system during
pressure testing
at pressures
greater than
1/2 psi.
Dryer
Gas
Pipe
The gas pipe that comes
out through
the rear of your dryer
has a 3/8" male pipe thread.
//
A
/
_---
9¼" ---_
(235 mm)
A. 3/8" NPT dryer pipe