Kenmore 8873 Use and Care Guide - Page 11
Optional, exhaust, installations, Alternate, for close, clearances, NOTE: The, Special, provisions,
![]() |
View all Kenmore 8873 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Optional exhaust installations This laundry center can be converted to exhaust out the right or left side. To convert the laundry center, use Side Exhaust Kit Part Number 279823. If your laundry center was previously exhausted from the right or left side, it can be converted to rear exhaust by using standard offset connections. To cover the hole in the side, one of the following plugs can be added: 692790 (white) 3979370 (graphite) 3977784 (biscuit) Follow the instructions in the kit to install. Kits are available from your local Sears store or Sears Service Center. NOTE: The following kits for close clearance alternate installations are available for purchase. Please see the service number located on the back page of this manual to order. • Over-The-Top Installation: Part Number 26-49909 Periscope Installation (For use with dryer vent to wall vent mismatch): Part Number 26-49901 - Less than 5 in. (12.7 cm) mismatch Part Number 26-49908 - 5 in. (12.7 cm) to 18 in. (45.7 cm) mismatch Part Number 26-49904 - 18 in. (45.7 cm) to 29 in. (73.7 cm) mismatch Part Number 26-49905 - 29 in. (73.7 cm) to 50 in. (127 cm) mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure. Do not use screws or other fastening devices that extend into the interior of the vent to secure vent. 1 2 3 1, Standard rear offset exhaust installation 2. Rearexhaust for offset close clearance connection 3, Left or right side exhaust installation Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. Three close-clearance installations are shown. Refer to the manufacturer's instructions provided with the vent system. Terminate the exhaust vent outside. The exhaust vent must not terminate beneath the mobile home and must not be connected to any other duct, vent or chimney. Determine Vent Length 1o Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 99° turns. 2 1. Loop system with standard elbows 2. Loop system with one offset & one stardard elbow 3. Vent system with one periscope [2 in. (5 cm) clearance] 11
![](/manual_guide/products/kenmore-8873-use-care-guide-17cd416/11.png)