Kenwood KW85 Use and Care Guide - Page 9

Installation - accessories

Page 9 highlights

GB/KW85 18-11-2003 14:02 Pagina 9 Installation CHOOSING THE INSTALLATION SITE Position the air conditioning unit on a flat surface where the air outlet grilles cannot be obstructed. Position the appliance at least 50 cm (19.7") away from walls or obstacles. INSTALLING THE AIR EXHAUST HOSE 1. Open out the end of the hose and screw the two adapters on counterclockwise (see figure). 2. Fit the square adapter on the air exhaust hose to the air exhaust outlet on the appliance. 3. Connect the other end (flange) to the nearest window. Important: the air exhaust hose must be between 500 mm (19.7") and 2000 mm (78.7") long. You are recommended to keep the air exhaust hose as short as possible. During installation, keep the hose as horizontal as possible without distorting it. Do not connect the terminal to other exhaust ducts (flue Flange square adapter CABLE WINDER Before installing the air exhaust hose, mount the two cable winder brackets using the screws supplied as shown in the figure. air exhaust outlet or chimney) as this could lead to malfunction. 130 cm (51.18 in) AIR EXHAUST ACCESSORIES hose length 500 mm (19.7") 2000 mm (78.7") adapter for flange flange 40 cm (15.7 in) adapter crosspiece 675 mm (26.5") - 1230 mm (48.4") (some models only) Correct wall installation: the hole must be at a height of between 40 cm (15.7") and 130 cm (51.18") from the floor. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

CHOOSING THE INSTALLATION SITE
Position the air conditioning unit on a flat sur-
face where the air outlet grilles cannot be
obstructed. Position the appliance at least 50
cm (19.7”) away from walls or obstacles.
CABLE WINDER
Before installing the air exhaust hose, mount
the two cable winder brackets using the
screws supplied as shown in the figure.
AIR EXHAUST ACCESSORIES
INSTALLING THE AIR EXHAUST HOSE
1.
Open out the end of the hose and screw the
two adapters on counterclockwise (see figu-
re).
2.
Fit the square adapter on the air exhaust hose
to the air exhaust outlet on the appliance.
3.
Connect the other end (flange) to the neare-
st window.
Important: the air exhaust hose must be
between 500 mm (19.7”) and 2000 mm
(78.7”) long. You are recommended to keep
the air exhaust hose as short as possible.
During installation, keep the hose as horizontal
as possible without distorting it.
Do not con-
nect the terminal to other exhaust ducts (flue
or chimney) as this could lead to malfunction.
Correct wall installation: the hole must be
at a height of between 40 cm (15.7”) and
130 cm (51.18”) from the floor.
9
Installation
(51.18 in)
130 cm
40 cm
(15.7 in)
hose length
500 mm (19.7”) -
2000 mm (78.7”)
flange
crosspiece 675 mm
(26.5”) - 1230 mm
(48.4”) (some models
only)
adapter
square adapter
air exhaust
outlet
Flange
adapter
for flange
GB/KW85
18-11-2003
14:02
Pagina 9