KitchenAid KBZU122VSS Use & Care Guide - Page 15
Gas Connection to Natural Gas or Local LP Gas, Plug in Side Burner
UPC - 883049184401
View all KitchenAid KBZU122VSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
5. Screw the gas pressure regulator/hose assembly to the 20 lb LP gas fuel tank as shown. (To disconnect, turn off the gas supply to the 20 lb LP gas fuel tank, then unscrew the gas pressure regulator/hose assembly from the 20 lb LP gas fuel tank as shown.) connect disconnect B A Copies of the standards listed above may be obtained from: CSA International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575 National Fire Protection Association One Batterymarch Park Quincy, Massachusetts 02269 1. Make gas connections. A combination of pipe fittings must be used to connect the side burner to the existing gas line. ■ If local codes permit, use an outdoor flexible stainless steel tubing gas connector, design-certified by CSA International, to connect the side burner to the rigid gas supply line. A ⁵⁄₈" diameter line is recommended. Using a wrench to tighten, connect the gas supply to the side burner. Use pipe-joint compound on all non-flared male threads. Do not kink or damage the flexible connector when moving the side burner. ■ Pipe-joint compounds suitable for use with LP gas must be used. Do not use TEFLON®† tape. A. 20 lb LP gas fuel tank B. Gas pressure regulator/hose assembly 6. Turn on the gas supply. Wait a few minutes for gas to move through the gas line. 7. Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found. 8. Slide tank tray back into the cabinet. 9. Go to "Plug in Side Burner" in this section. Gas Connection to Natural Gas or Local LP Gas WARNING A B C A. New CSA International approved "outdoor" flexible gas supply line B. Rear of side burner C. To Natural gas or Local LP gas supply 2. Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe. A B Explosion Hazard Use a new CSA International approved "outdoor" gas supply line. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 11" (28 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. A. Closed valve B. Open valve 3. Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found. Plug in Side Burner NOTE: This built-in outdoor side burner comes with a large 2,085 mAmp power transformer/plug assembly for the side burner igniters. Follow the instructions for plugging in and mounting the power transformer. Keep any electrical supply cord away from any heated surfaces. This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with either the National Fuel Gas Code ANSI Z223.1 - latest edition, or CAN/CGA-B149.1 Natural Gas and Propane installation code. †®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. 15