Natural Gas Conversion
UPC - 883049027555
View all KitchenAid KDRS807SSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
IMPORTANT: The TripleTier® Flame burner has 2 gas orifice spuds. Be sure to change the external gas orifice spud located under the plate. A Natural Gas Conversion WARNING B C A. Plate B. External gas orifice spud C. Internal gas orifice spud 4. Apply masking tape to the end of a 7 mm nut driver to help hold the internal gas orifice spud in the nut driver while changing it. Press nut driver down onto the internal gas orifice spud and remove by turning it counterclockwise and lifting out. Set internal gas orifice spud aside. 5. Use a 7 mm combination wrench to remove the external gas orifice spud. Turn counterclockwise to remove. Set external gas orifice spud aside. 6. Replace the Natural gas orifice spud with the correct LP gas orifice spud. Refer to the following chart for correct LP gas orifice spud placement. LP Gas Orifice Spud Chart for TripleTier® Flame Burners Burner Location Burner Rating Color Size Left front (external TripleTier® burner) 11,800 Btu/h Brown 1.00 mm Left front (internal TripleTier® burner) 2,200 Btu/h Orange 0.42 mm 7. Replace burner plate, head and cap. 8. Place Natural gas orifice spuds in plastic parts bag for future use and keep with the package containing literature. 9. Reinstall the warming drawer. See the "Replace Oven Racks and Warming Drawer" section for instructions. 10. Complete installation. See "Make Gas Connection" and "Electronic Ignition System" sections. Checking for proper cooktop burner flames is very important. The small inner cone should have a very distinct blue flame ¼" to ½" long. The outer cone is not as distinct as the inner cone. LP gas flames have a slightly yellow tip. IMPORTANT: You may have to adjust the "LO" setting for each cooktop burner. Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. To Convert Gas Pressure Regulator 1. Turn manual shutoff valve to the "closed" position. B A C A. To range B. Manual shutoff valve "closed" position C. Gas supply line 2. Unplug range or disconnect power. 3. Remove warming drawer. See the "Remove Warming Drawer" section for instructions. Locate gas pressure regulator at rear of warming drawer compartment. 4. Remove access cover from the gas pressure regulator. A A. Gas pressure regulator IMPORTANT: Do not remove the gas pressure regulator. Gas pressure regulator 5. Remove the access cap by using a wrench, turning the access cap counterclockwise. 6. Remove spring retainer from the cap by pushing against the flat side of the spring retainer. Look at the spring retainer to locate the "LP" or "NAT" position. 7. Turn over the spring retainer so the "NAT" is showing on the bottom. 8. Snap the spring retainer back into the cap. 21