KitchenAid KEWS145SSS Installation Guide - Page 3
Warning - installation
![]() |
UPC - 883049035154
View all KitchenAid KEWS145SSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Cabinet Front View Electrical Requirements WARNING 120 volt grounded outlet (or located in adjacent cabinet) Warming drawer cutouts Toe kick 2¹/₂" (6.4 cm) min. 9¹/₈" (23.2 cm) 2¹/₂" (6.4 cm) min. 9¹/₈" (23.2 cm) Recommended 4¹/₄" (10.8 cm) Minimum 1" (2.5 cm) 4" (10.2 cm) A B WARMING DRAWER SIZE CUTOUT WIDTH (A) MIN. CABINET WIDTH (B) 24" (61 cm) 27" (68.6 cm) 30" (76.2 cm) 22¹⁄₂" (57.1 cm) 25¹⁄₂" (64.8 cm) 28¹⁄₂" (72.4 cm) 24" (61 cm) 27" (68.6 cm) 30" (76.2 cm) Warming drawer can be installed as an indoor single or double installation or installed under a single oven. Two warming drawers under a single oven are shown. NOTE: The warming drawer cannot be leveled after being installed. For outdoor installation follow the cutout dimensions above. Install the outdoor warming drawer in a permanent fixture. Custom Wood Drawer Front If you plan to install a custom wood panel to match your cabinets, we recommend consulting a qualified cabinetmaker or carpenter. The back of the wood panel must be sealed to avoid moisture damage. Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. IMPORTANT: The warming drawer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1. If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate. A copy of the above code standards can be obtained from: National Fire Protection Association One Batterymarch Park Quincy, MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575 ■ A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this warming drawer be provided. ■ The model/serial rating plate is located above the left-hand side receiving slide. The warming drawer must be removed to view the model/serial rating plate. See the illustration below. A A. Model/serial number plate 3
![](/manual_guide/products/kitchenaid-kews105sss-installation-guide-8870d75/3.png)