Konica Minolta bizhub PRO C1060L bizhub PRESS C1070/C1070P/C1060/bizhub PRO C1 - Page 76

HTML User's Guide, Relay Unit RU-509

Page 76 highlights

5.2 Image Quality Adjustment Adjustment order 4-a 4-b 5 Menu item Description Reference Color Density Control (with Relay Unit RU-509 mounted) Calibration by image controller (without Relay Unit RU-509 mounted) Exact Color Basic Setting Configure a setting so that this machine executes calibration automatically at periodic intervals. Color Density Manual Control Executes calibration at any timing in addition to the periodic adjustment. Each Paper Type Color Adj. Adjusts the sensor sensitivity to fit the paper. This function is available when using colored paper or enhancing the sensor accuracy. On the [MACHINE] screen, select [Adjustment] - [Color Density Control] - [Each Paper Type Color Adj.] to adjust the sensitivity. Executes calibration using Color Centro. Executes calibration for color mixture. This function can be used to improve the gray balance. p. 5-15 p. 5-18 HTML User's Guide p. 5-21 HTML User's Guide Carry out the adjustment continuously in sequence. If you have interrupted the adjustment, select "2. Gamma Automatic Adj." to execute automatic gamma adjustment each time before restarting calibration. For example, if you have interrupted the adjustment at the end of the "3. Density Balance Adjustment" processing, select "2. Gamma Automatic Adj." - "4-a. Color Density Control (with Relay Unit RU-509 mounted)" or "4-b. Calibration by image controller (without Relay Unit RU-509 mounted)" to restart the adjustment. If sufficient adjustment results are not obtained via daily maintenance, also carry out the adjustment in this order. For details about the setting procedure, refer to the HTML User's Guide. NOTICE If the setting value is changed in the [Custom Screen], hue may fluctuate significantly. To manage the hue fluctuation, specify the standard image quality following the procedure if you changed the setting value. 5-27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139

5-27
5.2
Image Quality Adjustment
Carry out the adjustment continuously in sequence. If you have interrupted the adjustment, select "2. Gamma Auto-
matic Adj." to execute automatic gamma adjustment each time before restarting calibration. For example, if you have
interrupted the adjustment at the end of the "3. Density Balance Adjustment" processing, select "2. Gamma Automatic
Adj." - "4-a. Color Density Control (with
Relay Unit RU-509
mounted)" or "4-b. Calibration by image controller (without
Relay Unit RU-509
mounted)" to restart the adjustment.
If sufficient adjustment results are not obtained via daily maintenance, also carry out the adjustment in this order.
For details about the setting procedure, refer to the
HTML User's Guide
.
NOTICE
If the setting value is changed in the [Custom Screen], hue may fluctuate significantly. To manage the hue fluctuation,
specify the standard image quality following the procedure if you changed the setting value.
4-a
Color Density
Control (with
Re-
lay Unit RU-509
mounted)
Basic Setting
Configure a setting so that this
machine executes calibration
automatically at periodic inter-
vals.
p. 5-15
Color Density
Manual Control
Executes calibration at any tim-
ing in addition to the periodic
adjustment.
p. 5-18
Each Paper Type
Color Adj.
Adjusts the sensor sensitivity to
fit the paper. This function is
available when using colored
paper or enhancing the sensor
accuracy.
On the [MACHINE] screen, se-
lect [Adjustment] - [Color Densi-
ty Control] - [Each Paper Type
Color Adj.] to adjust the sensitiv-
ity.
HTML User's
Guide
4-b
Calibration by im-
age controller
(without
Relay
Unit RU-509
mounted)
Executes calibration using
Color Centro
.
p. 5-21
5
Exact Color
Executes calibration for color mixture.
This function can be used to improve the gray bal-
ance.
HTML User's
Guide
Adjustment
order
Menu item
Description
Reference