Konica Minolta magicolor 1600W Service Manual - Page 97

Fan control, Composition, Operation

Page 97 highlights

magicolor 1600W magicolor 1650EN 19. Fan control 19. Fan control 19.1 Composition Theory of Operation Ver. 1.0 Nov. 2008 DC power supply fan motor (FM1) Suction Exhaust Ozone ventilation fan motor (FM2) A034T2C549AA 19.2 Operation 19.2.1 Function Motor name Function (purpose) DC power supply fan motor (FM1) To discharge heat stagnant inside the machine to the outside to prevent the temperature of the DC power supply from rising. Ozone ventilation fan motor (FM2) To recover toner powder in the imaging cartridge. To draw ozone produced in the imaging cartridge to the outside. COMPOSITION/ OPERATION 70

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

19. Fan control
Theory of Operation
V
er. 1.0
N
ov. 200
8
70
magicolor 1600W
magicolor 1650EN
COMPOSITION/
OPERATION
19.
Fan control
19.1
Composition
19.2
Operation
19.2.1
Function
A034T2C549AA
Suction
Ozone ventilation fan motor (FM2)
Exhaust
DC power supply fan motor (FM1)
Motor name
Function (purpose)
DC power supply fan motor (FM1)
To discharge heat stagnant inside the machine to the outside to
prevent the temperature of the DC power supply from rising.
Ozone ventilation fan motor (FM2)
To recover toner powder in the imaging cartridge.
To draw ozone produced in the imaging cartridge to the outside.