Konica Minolta magicolor 5670EN magicolor 5650/5670 Reference Guide - Page 396
Choices: None, Auth-password, Default: Auth-password/Priv-password
View all Konica Minolta magicolor 5670EN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 396 highlights
Item Description Read Security Level Specifies the security level for read only user. Choices: None, Auth-password, Auth-password/ Priv-password Default: Auth-password/Priv-password Read Specifies the read only user authentication pass- Auth-pass- word to be used for authentication. word Range: 8 to 32 characters Default: AuthPassword Read Priv-password Specifies the read only user privacy password to be used for privacy (encryption). Range: 8 to 32 characters Default: PrivPassword Write User Specifies the reading/writing user name. Name Range: Up to 32 characters Default: restrict " The same name specified as the Discovery user name cannot be used. Write Security Level Specifies the security level for reading/writing user. Choices: None, Auth-password, Auth-password/ Priv-password Default: Auth-password/Priv-password Write Specifies the reading/writing user authentication Auth-pass- password to be used for authentication. word Range: 8 to 32 characters Default: (excluding colons) Write Priv-password Specifies the reading/writing user privacy password to be used for privacy (encryption). Range: 8 to 32 characters Default: (excluding colons) 376 Configuring the Printer