Kyocera KM-C3225E PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 67
Clsp
View all Kyocera KM-C3225E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
CLSP CLSP - CLoSe Path Format CLSP; Parameter None Function The CLSP command closes an open path by adding a line segment extending from the end of the path to the beginning of the path. Simply ending a path at the path's starting point does not make it a closed path; such a path remains open until it is closed. Closure can be made either explicitly, by means of the CLSP command, or implicitly by means of the FILL (FILL current path) command. File !R! RES; UNIT C; NEWP; CMNT The 1 st path below is stroked without closing; SPD .25; PMZP 5, 10; PMRA 5, 10, 1, 90; PARC 5, 10, 1, 90, 270; PARC 7, 10, 1, 270, 90; STRK; NEWP; CMNT Next path is closed by CLSP before stroked; PMZP 5, 14; PMRA 5, 14, 1, 90; PARC 5, 14, 1, 90, 270; PARC 7, 14, 1, 270, 90; CLSP; STRK; PAGE; EXIT; 57