Test Run Outdoor unit related error Display Title Cause of Error 1 Master Outdoor Unit Air Temperature Sensor Fault Master Outdoor Unit Air Temperature Sensor open or short 4 4 2 Slave1 Outdoor Unit Air Temperature Sensor Fault Slave1 Outdoor Unit Air Temperature Sensor open or short 3 Slave2 Outdoor Unit Air Temperature Sensor Fault Slave2 Outdoor Unit Air Temperature Sensor open or short Master Outdoor Unit Heat 1 Exchanger Temperature Sensor (Front side) Fault Master Outdoor Unit Heat Exchanger Temperature Sensor(Front side) open or short Slave1 Outdoor Unit Heat 4 5 2 Exchanger Temperature Sensor (Front side) Fault Slave1 Outdoor Unit Heat Exchanger Temperature Sensor (Front side) open or short Slave2 Outdoor Unit Heat 3 Exchanger Temperature Sensor (Front side) Fault Slave2 Outdoor Unit Heat Exchanger Temperature Sensor(Front side) open or short 1 Master Outdoor Unit Suction Temperature Sensor Fault Master Outdoor Unit Suction Temperature Sensor open or short 4 6 2 Slave1 Outdoor Unit Suction Temperature Sensor Fault Slave1 Outdoor Unit Suction Temperature Sensor open or short 3 Slave2 Outdoor Unit Suction Temperature Sensor Fault Slave2 Outdoor Unit Suction Temperature Sensor open or short Master Outdoor Unit Constant 1 Speed Compressor Discharge Temperature Sensor Fault Master Outdoor Unit Constant Speed Compressor Discharge Temperature Sensor open or short Slave1 Outdoor Unit Constant 4 7 2 Speed Compressor Discharge Temperature Sensor Fault Slave1 Outdoor Unit Constant Speed Compressor Discharge Temperature Sensor open or short Slave2 Outdoor Unit Constant 3 Speed Compressor Discharge Temperature Sensor Fault Slave2 Outdoor Unit Constant Speed Compressor Discharge Temperature Sensor open or short Master Outdoor Unit Heat 1 Exchanger Temperature Sensor (Rear side) Fault Master Outdoor Unit Heat Exchanger Temperature Sensor (Rear side) open or short Slave1 Outdoor Unit Heat 4 8 2 Exchanger Temperature Sensor (Rear side) Fault Slave1 Outdoor Unit Heat Exchanger Temperature Sensor (Rear side) open or short Slave2 Outdoor Unit Heat 3 Exchanger Temperature Sensor (Rear side) Fault Slave2 Outdoor Unit Heat Exchanger Temperature Sensor (Rear side) open or short 1 Omitting connection of R, S, T power of Master Outdoor Unit Omitting connection of Master outdoor unit 5 0 2 Omitting connection of R, S, T power of Slave1 Outdoor Unit Omitting connection of Slave1 Outdoor Unit 3 Omitting connection of R, S, T power of Slave2 Outdoor Unit Omitting connection of Slave2 Outdoor Unit Excessive capacity of indoor units Excessive connection of indoor units compared to 511 capacity of Outdoor Unit 82 Outdoor Unit