Part 3 INITIAL STEPS FOR INSTALLING YOUR DRYER STEP 3: Connecting the Exhaust and Venting System. In addition to the following warnings, please refer to manual section on Exhaust Requirements and Maintenance. IMPORTANT: To reduce the risk of fire, combustion, and gas accumulation, the dryer must be vented to the outdoors. Please follow the instructions (and all others in this manual) very carefully. I ALTERNATE EXHAUST DIRECTIONS 1. Remove screw & exhaust duct. 2. Detach and remove the bottom, left, or right side knockout as desired. (Right side vent not avilable on gas dryer.) • Do not use thin plastic or foil ducting. • Use 4" (10.2 cm) diameter rigid or flexible metal duct (note: venting materials are not supplied with the dryer, and you should obtain the venting materials necessary for proper installation) • Position the dryer where the exhaust duct is shorter as possible • Clean old ducts before installing this dryer • The male end of each section of exhaust duct must point away from the dryer • Use fewer elbow joints as possible • Use duct tape on all duct joints • Insulate ductwork that runs through unheated areas in order to reduce condensation and lint build-up on pipe walls; and • PLEASE BE AWARE THAT FAILURE TO EXHAUST THE DRYER CORRECTLY WILL VOID THE DRYER'S WARRANTY. ! WARNING! • Use a heavy metal vent. • Do not use a plastic vent. • Do not use a metal foil vent. • Failure to follow these instructions can result in death or fire. • Clean old ducts before installing this dryer Attach hole 3. Reconnect the new duct[11 in(28cm)] to the blower housing, and Fixing the duct to the base. 4. Pre-assemble 4" elbow with 4" duct. Wrap duct tape around joint. 5. Insert elbow duct assembly first, through the side opening and connect the elbow to the dryer internal duct. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

9
Part 3
INITIAL STEPS FOR INSTALLING YOUR DRYER
In addition to the following warnings, please refer
to manual section on Exhaust Requirements and
Maintenance.
IMPORTANT:
To reduce the risk of
fire, combustion, and gas accumulation, the dryer
must be vented to the outdoors.
Please follow the
instructions (and all others in this manual) very
carefully.
• Do not use thin plastic or foil ducting.
• Use 4" (10.2 cm) diameter rigid or flexible metal
duct (note:
venting materials are not supplied with
the dryer, and you should obtain the venting
materials necessary for proper installation)
• Position the dryer
where the exhaust duct is
shorter as possible
Clean old ducts before installing this dryer
• The male end of each section of exhaust duct must
point away from the dryer
• Use fewer elbow joints as possible
• Use duct tape on all duct joints
• Insulate ductwork that runs through unheated
areas in order to reduce condensation and lint
build-up on pipe walls; and
PLEASE BE AWARE THAT FAILURE TO
EXHAUST THE DRYER CORRECTLY WILL
VOID THE DRYER’S WARRANTY.
STEP 3:
Connecting the Exhaust
and Venting System.
WARNING!
• Use a heavy metal vent.
• Do not use a plastic vent.
• Do not use a metal foil vent.
• Failure to follow these instructions can
result in death or fire.
• Clean old ducts before installing this dryer
!
ALTERNATE EXHAUST DIRECTIONS
1
.
Remove screw & exhaust duct.
2
.
Detach and remove the bottom, left, or right
side knockout as desired.
(Right side vent not avilable on gas dryer.)
3
.
Reconnect the new duct[11 in(28cm)] to the
blower housing, and Fixing the duct to the
base.
4
.
Pre-assemble 4" elbow with 4" duct.
Wrap duct tape around joint.
5
.
Insert elbow duct assembly first, through the
side opening and connect the elbow to the
dryer internal duct.
Attach
hole