Component 13. Outlet Thermostat (Auto reset) Test Procedure Measure resistance of terminal to terminal Open at 203 ± 7°F (95 ± 5°C) Close at 158 ± 9°F (70 ± 5°C) Check result Resistance value ∞ Continuity < 1Ω Remark • Gas type • Gas funnel • Check Top Marking: N95 14. Outlet Thermostat (Manual reset) • Check Top Marking: N100 Measure resistance of terminal to terminal Open at 212 ± 12°F (100 ± 7°C) Manual reset If thermal fuse is open must be replaced Resistance value ∞ Continuity < 1Ω • Gas type • Gas funnel 15. Semi-Conductor R BW Measure resistance of terminal to terminal Red-White : 300 ± 20 Ω White-Black : 300 ± 20 Ω Resistance value ∞ Continuity < 1Ω • Elect type • Gas type 16
16
Component
Test Procedure
Check result
Remark
13. Outlet Thermostat
(Auto reset)
• Check Top Marking:
N95
Measure resistance of terminal
to terminal
±
Open at 203 ± 7°F (95 ± 5°C)
²
Close at 158 ± 9°F (70 ± 5°C)
±
Resistance value
≒
∞
²
Continuity < 1Ω
• Gas type
• Gas funnel
14. Outlet Thermostat
(Manual reset)
• Check Top Marking:
N100
15. Semi-Conductor
Measure resistance of terminal
to terminal
±
Open at 212 ± 12°F
(100 ± 7°C)
²
Manual reset
Measure resistance of
terminal to terminal
±
Red-White :
300 ± 20 Ω
²
White-Black :
300 ± 20 Ω
If thermal fuse is open must
be replaced
±
Resistance value
≒
∞
²
Continuity < 1Ω
±
Resistance value
≒
∞
²
Continuity < 1Ω
• Gas type
• Gas funnel
• Elect type
• Gas type
B
W
R