LG DLE7177WM Service Manual - Page 31

Test 8

Page 31 highlights

Test 8 Semi Conductor Caution Before measuring resistance, be sure to turn Power off, and do voltage discharge. (When discharging, contact the metal plug of Power cord with earth line.) Trouble Symptom Degree of Resistance is not in 300°æ30 Ω Measurement Condition Turn the Dryer's Power Off, then measure resistance. Take 6pin Connector from the Controller. When measuring resistance Is resistance 300 20 Ω? NO YES • Check Semiconductor and Harness Connector • Check Harness linking connector When measuring resistance in Semi-Conductor Is resistance 300 20 Ω? 1. Is the measurement within the range of 300 20 Ω between Red-White? 2. Is the measurement within the range of R BW 300 20 Ω between Black-White? NO • Replace Control and Check. YES Normal Condition 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

30
Test 8
Semi Conductor
Caution
Trouble Symptom
Measurement Condition
Before measuring resistance, be sure to turn Power off, and do voltage discharge.
(When discharging, contact the metal plug of
Power cord with earth line.)
Degree of Resistance is not in 300°æ30 Ω
Turn the Dryer’s Power Off, then measure resistance.
Normal Condition
When measuring resistance
Is resistance 300
20 Ω?
YES
NO
When measuring resistance in Semi-Conductor
Is resistance 300
20 Ω?
1. Is the measurement within the range of
300
20 Ω between Red-White?
2. Is the measurement within the range of
300
20 Ω between Black-White?
YES
NO
• Replace Control
and Check.
• Check Semi-
conductor and
Harness Connector
• Check Harness
linking connector
Take 6pin Connector from
the Controller.
B
W
R