LG DLG2522W Service Manual - Page 17

Outlet Thermostat - thermostat reset

Page 17 highlights

Component 13. Outlet Thermostat (Auto reset) • Check Top Marking: N95 13. Outlet Thermostat (Manual reset) • Check Top Marking: N100 Test Procedure Measure resistance of terminal to terminal Open at 203 ± 7°F (95 ± 5°C) Close at 158 ± 9°F (70 ± 5°C) Check result Resistance value ∞ Continuity < 1Ω Remark • Gas type • Gas funnel Measure resistance of terminal to terminal Open at 212 ± 12°F (100 ± 7°C) Manual reset If thermal fuse is open must be replaced Resistance value ∞ Continuity < 1Ω • Gas type • Gas funnel 16