LG DLG2522W Service Manual - Page 28

Test 7

Page 28 highlights

Test 7 GAS Valve test - Gas Type Caution When measuring power, be sure to wear insulated gloves, to avoid electric shock. Trouble Symptom While operating, Heating will not work. Drying time takes longer. Measurement Condition With dryer power on Valve 1 Igniter Valve 2 Power On & Start (Normal Cycle) NO When measuring Valve 1 voltage, More than DC 90V? YES NO • Check thermostat Hi limit Safety Igniter operates? (after 1 min, Igniter becomes reddish) YES NO • Check Igniter & Frame detect When measuring Valve 2 voltage, Value is more than DC 90V? (10 sec after Igniter off) YES NO • Check Gas connection or Gas supply When measuring terminal resistance on Valve 1 and Valve 2, Valves are more than1.5 ~ 2.5kΩ? YES (Measure after Off ) NO • Change Valve If "Valve 1 " and "Valve 2" are under DC 10V, Valves are Off? NO YES • Change Valve • Harness check • Controller change 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

27
Test 7
GAS Valve test - Gas Type
Caution
Trouble Symptom
Measurement Condition
When measuring power, be sure to wear insulated gloves, to avoid electric shock.
While operating, Heating will not work.
Drying time takes longer.
With dryer power on
• Harness check
• Controller change
When measuring terminal resistance on Valve 1 and
Valve 2, Valves are more than1.5 ~ 2.5kΩ?
(Measure after
Off )
NO
YES
• Change Valve
• Change Valve
• Check thermostat
Hi limit Safety
Igniter operates?
(after 1 min, Igniter becomes reddish)
YES
NO
• Check Igniter &
Frame detect
When measuring Valve 2 voltage, Value is more
than DC 90V? (10 sec after Igniter off)
NO
YES
• Check Gas
connection or
Gas supply
When measuring Valve 1 voltage,
More than
DC 90V?
YES
NO
If “Valve 1 “ and “Valve 2” are under DC 10V, Valves
are Off?
YES
NO
Power On & Start (Normal Cycle)
NO
Igniter
Valve 2
Valve 1