LG DLGX4371K Owners Manual - Page 13
Installation Location Requirements, Clearances
![]() |
View all LG DLGX4371K manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
ENGLISH INSTALLATION 13 Installation Location Requirements wWarning Read all installation instructions completely before installing and operating your dryer! It is important that you review this entire manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust requirements are provided on the following pages. • A location that allows for proper exhaust installation. A gas dryer must be exhausted to the outdoors. See Venting the dryer. • A grounded electrical outlet located within 2 ft. (61 cm) of either side of the dryer. See Connecting Electric Dryers. • A sturdy floor to support the total dryer weight of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered. • No other fuel-burning appliance can be installed in the same closet as a dryer. Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector. NOTE • Floor must be level, with a maximum slope of 1 inch (2.5 cm) under entire dryer. Clothes may not tumble properly, and automatic sensor cycles may not operate correctly if dryer is not level. • For a garage installation, you will need to place the dryer at least 18 inches (46 cm) above the floor. If using a pedestal, you will need 18 inches (46 cm) to the bottom of the dryer. Clearances 14" max.* (35.6 cm) 18" min.* (45.7 cm) 48 in.2* (310 cm2) 24 in.2* (155 cm2) 1"* 30'' 5"** (2.5 cm) (76.2cm) (12.7 cm) 3"* (7.6 cm) 14" max.* (35.6 cm) 18" min.* (45.7 cm) 0" (0 cm) 38" min. (96.52 cm) 3"* (7.6 cm) 1" (2.5 cm) 27'' (68.6cm) 1" 1"* 30'' 5"** (2.5 cm) (2.5 cm) (76.2cm) (12.7 cm) 1"* (2.5 cm) 27" 1"* (68.6 cm) (2.5 cm) 3"* Installation s1(345p",6macamx.c)* in48gin.2f* or recesse(7d,6 cam)rea or closet 14" max.* installatio(n35,6 cm) The following cl1e8"amrina.*nc(3e10scma2)re recommended for this dryer. Although this (1d485"r,7mycinem.*)r h(a00cs"mb) een tested for 1inch (2.5cm) clearance on th(e45,7scimd)es and rear, the recommended clearances should be considere38d" mfino. r the following reasons: (96,52 cm) • Additional clearance sh24oin.u2* ld installation and servic(1i5n5 cgm.2) be conside3r"*ed (7,6 cm) for ease of 1"* 30'' 5"** 1" 27'' • Additio(n2,5acml )c(l7e6,2acrma) n(12c,7ecms) might be required fo(2r,5wcma) ll, d(6o8,6ocmr) and floor moldings. • Additional clearance should b1"e* consid27"ered o1n"* all sides of the dryer to reduce noise (t2,r5acmn)sfer(6.8,6 cm) (2,5 cm) 1" 1"* 30'' 5"** (2,5 cmF) o(r2,5cclmo) se(7t6,i2ncms)ta(1l2l,7actmi)on, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. • Companion appliance clearances should also be considered. NOTE There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of vibration from one to the other. With enough vibration, the appliances will make noise or touch each other causing paint damage and making even more noise. MFL67731085_en_170711.indd 13 2017.7.11 4:4:36 PM
![](/manual_guide/products/lg-dlgx4371k-owners-manual-36850c2/13.png)