Cautions for disassembling the product
View all LG GR-K192AF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Cautions for disassembling the product Chapter 10. Cautions for disassembling the product 10-1. PWB (PCB) assembly, main • When disassembling the PWB (PCB) assembly, main located in the mechanical room, be careful so that the lead wires do not touch the edge part. • If the lead wire coating is disconnected or the coating is damaged, it can cause a short circuit. 10-2. Frame assembly, display • First left and right Doco case remove. And using the driver, open the slot between the frame display and the case-U to disassemble the unit. At this time, be careful not to apply too much pressure to damage the PWB (PCB) assembly, display or make scratches on frame display and case-U. g Depending on the mode, the service slot is on the top left or right side. Frame Display Case-U Deco, Case - 52 -