LG HBLG1003R Service Manual - Page 16

Electrical Parts

Page 16 highlights

Disassembly 6. SHROUD 1. Remove the fan. 2. Remove the shroud. (See Figure 23) 3. Re-install the components by referring to the removal procedure, above. Figure 23 Electrical Parts 1. OVERLOAD PROTECTOR 1. Remove the cabinet. 2. Remove the nut which fastens the terminal cover. 3. Remove the terminal cover. (See Figure 24) 4. Remove all the leads from the overload protector. 5. Remove the overload protector. 6. Re-install the components by referring to the removal procedure, above. 2. COMPRESSOR 1. Remove the cabinet. 2. Discharge the refrigerant system using a FreonTM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system. 3. Remove the overload protector. 4. After purging the unit completely, unbraze the suction and discharge tubes at the compressor connections. 5. Remove the 3 nuts and the 3 washers which fasten the compressor. 6. Remove the compressor. (See Figure 25) 7. Re-install the components by referring to the removal procedure, above. Figure 24 Figure 25 16 Room Air Conditioner

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

16
Room Air Conditioner
Disassembly
6.
SHROUD
1. Remove the fan.
2. Remove the shroud. (See Figure 23)
3. Re-install the components by referring to the
removal procedure, above.
1
.
OVERLOAD PROTECTOR
1. Remove the cabinet.
2. Remove the nut which fastens the terminal cover.
3. Remove the terminal cover. (See Figure 24)
4. Remove all the leads from the overload protector.
5. Remove the overload protector.
6. Re-install the components by referring to the
removal procedure, above.
2
.
COMPRESSOR
1. Remove the cabinet.
2. Discharge the refrigerant system using a Freon
TM
Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before venting
the Freon
TM
. Leave the valve in place after
servicing the system.
3. Remove the overload protector.
4. After purging the unit completely, unbraze the
suction and discharge tubes at the compressor
connections.
5. Remove the 3 nuts and the 3 washers which
fasten the compressor.
6. Remove the compressor. (See Figure 25)
7. Re-install the components by referring to the
removal procedure, above.
Figure
23
Figure
24
Figure
25
Electrical Parts