LG HBLG1003R Service Manual - Page 18

Refrigerating Cycle

Page 18 highlights

Disassembly 5. MOTOR 1. Remove the cabinet. 2. Remove the turbo fan. 3. Remove the fan. 4. Remove the 4 screws which fasten the motor from the air guide. (See Figure 28) 5. Remove the motor. 6. Re-install the components by referring to the removal procedure, above.(See Figure 28) Figure 28 Refrigerating Cycle 1. CONDENSER CAUTION: Discharge the refrigerant system using a FreonTM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system. 1. Remove the cabinet. 2. Remove the 5 screws which fasten the brace. 3. Remove the 5 screws which fasten the condenser and shroud. 4. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections. 5. Remove the condenser. 6. Re-install the components by referring to notes. (See Figure 29) Figure 29 2. EVAPORATOR 1. Remove the control box. 2. Remove the air guide upper. 3. Remove the 2 screws which fasten the evaporator. 4. Move the evaporator sideways carefully. 5. After discharging the refrigerant completely, unbraze the interconnecting tube at the evaporator connections. 6. Remove the evaporator. 7. Re-install the components by referring to notes. (See Figure 30) Figure 30 18 Room Air Conditioner

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

Disassembly
18
Room Air Conditioner
5
.
MOTOR
1. Remove the cabinet.
2. Remove the turbo fan.
3. Remove the fan.
4. Remove the 4 screws which fasten the motor from
the air guide. (See Figure 28)
5. Remove the motor.
6. Re-install the components by referring to the
removal procedure, above.(See Figure 28)
1
.
CONDENSER
1. Remove the cabinet.
2. Remove the 5 screws which fasten the
brace.
3. Remove the 5 screws which fasten the condenser
and shroud.
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the condenser
connections.
5. Remove the condenser.
6. Re-install the components by referring to notes.
(See Figure 29)
2
.
EVAPORATOR
1. Remove the control box.
2. Remove the air guide upper.
3. Remove the 2 screws which fasten the evaporator.
4. Move the evaporator sideways carefully.
5. After discharging the refrigerant completely,
unbraze the interconnecting tube at the evaporator
connections.
6. Remove the evaporator.
7. Re-install the components by referring to notes.
(See Figure 30)
Figure
28
Figure
29
Figure
30
Refrigerating Cycle
CAUTION:
Discharge the refrigerant system using a Freon
TM
Recovery System. If there is no valve
to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon
TM
. Leave
the valve in place after servicing the system.