LG LFC25770SW Owner's Manual - Page 32
Connecting The Water Line - compressor
View all LG LFC25770SW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
CONNECTING THE WATER LINE 9. CONNECT THE TUBING TO THE REFRIGERATOR Removing and Replacing Valve Cover. NOTE: • Before making the connection to the refrigerator, be sure the refrigerator power cord is not plugged into the wall outlet. 1. Remove the plastic flexible cap from the water valve. 10. TURN THE WATER ON AT THE SHUTOFF VALVE Tighten any connections that leak. Reattach the compressor compartment access cover. 2. Place the compression nut and ferrule (sleeve) onto the end of the tubing as shown. 3. lnsert the end of the copper tubing into the connection as far as possible. While holding the tubing, tighten the fitting. CAUTION : Check to see if water dripping occurs at water line connections. 11. PLUG IN THE REFRIGERATOR Arrange the coil of tubing so that it does not vibrate against the back of the refrigerator or against the wall. Push the refrigerator back to the wall. Tubing Clamp 1/4 " Compression Nut Ferrule (sleeve) 1/4 " Tubing Refrigerator Connection 12. START THE ICEMAKER Set the icemaker power switch to the ON position. The icemaker will not begin to operate until it reaches its operating temperature of 15°F (-9°C) or below. It will then begin operation automatically if the icemaker power switch is in the I (on) position. 32