LG LFX28968SW Service Manual - Page 28
Replace Main PCB
View all LG LFX28968SW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
8-5 Defrost Heater Error (Er dH) No Checking flow Result & SVC Action 1 Check the Door gasket. Part Result SVC Action 2 Check the Defrost control part. Fuse-M 0 Ω Other Go to the 3 Change Controller Assembly (Position No.400A ) Fust M Def' Sensor 34~42 Ω Go to the 3 Defrost Heater Other Change Controller Assembly (Position No.400A ) Def' Heater Defrost Sensor 0 Ω OFF Go to the 3 Replace product 3 Input Test 3 Mode. (Push the button 3 times) 4 Check the Blue(Pin4) to Orange(Pin9) at CON3 on the main PCB 5 Release the test mode. push the button 1 times. (normal) Result 112 ~ 116 V 0 V SVC Action Go to the 5 Replace Main PCB 6 Check the Blue(Pin4) to Orange(Pin9) at CON3 on the main PCB Result 0 V 112 ~ 116 V SVC Action Explain to customer Replace Main PCB - 28 -