No Checking flow 5 Damper checking method. Inputting TEST Mode, Check the damper and PCB. (1) (2) (3) (4) 6 Check the Fan motor. Rotate fan using your hand. Stuck change the motor. (Cause of ice or rust inside of motor) Result & SVC Action Test Damper Mode State 1 Mode Open 2 Mode Closed 1,2 Not mode working SVC Action Damper is normal. (Go to 6) Change the damper Point (1) to (2) (3) to (4) Result 370 ~450Ω Other 370 ~450Ω Other SVC Action It's normal Change damper It's normal Change damper Point Motor Result Sticky Not Sticky SVC Action Change the motor Change the PCB - 39 -