LG LRFDS3016D Owners Manual - Page 22
Saddle-Type Shutoff Valve
View all LG LRFDS3016D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
22 INSTALLATION 5 Tighten the pipe clamp. Tighten the clamp screws until the sealing washer begins to swell. NOTE Do not over tighten the clamp or you may crush the tubing. a Pipe Clamp b Inlet End c Clamp Screw d Washer 6 Route the tubing. Route the tubing between the cold water line and the refrigerator. Route the tubing through a hole drilled in the wall or floor (behind the refrigerator or adjacent base cabinet) as close to the wall as possible. NOTE Be sure there is sufficient extra tubing (about 8 ft. coiled into three turns of about 10 in. diameter) to allow the refrigerator to move out from the wall after installation. 7 Connect the tubing to the valve. Place the compression nut and ferrule (sleeve) for copper tubing onto the end of the tubing and connect it to the shutoff valve. Make sure the tubing is fully inserted into the valve. Tighten the compression nut securely. a Saddle-Type Shutoff Valve b Compression Nut c Packing Nut d Outlet Valve e Ferrule (sleeve) 8 Flush out the tubing. Turn the main water supply on and flush out the tubing until the water is clear. Shut the water off at the water valve after about one quart of water has been flushed through the tubing. 9 Connect the tubing to the refrigerator. NOTE Before making the connection to the refrigerator, be sure that the refrigerator power cord is not plugged into the wall outlet. Remove the flexible plastic cap from the water valve. Place the compression nut and ferrule (sleeve) onto the end of the tubing as shown.