LG LWHD8008R Service Manual - Page 19

Fails to Start - capacitor

Page 19 highlights

Check of power source. Check of control switch setting. Fails to Start Compressor fails only to start. Drop of power voltage. Defect of compressor capacitor. Capacitor check. Replacement. Improper thermostat setting Loose terminal connection Improper wiring Irregular motor resistance (Ω) Irregular motor insulation (Ω) Replacement of compressor (Motor damaged). -18- Check of circuit breaker and fuse. Gas leakage of feeler bulb of thermostat. Check control switch. Fan only fails to start. Improper wiring. Defect of fan motor capacitor. Irregular motor resistance (Ω) Irregular motor insulation (Ω) Replacement of fan motor. Regular but fails to start. Replacement of compressor. (Locking of piston, metal.)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

—18—
Fails to Start
Improper thermostat
setting
Loose terminal
connection
Improper wiring
Check of power source.
Drop of power voltage.
Capacitor check.
Replacement.
Check of control switch
setting.
Compressor fails only to
start.
Defect of compressor
capacitor.
Replacement of compressor
(Motor damaged).
Irregular motor insulation (
)
Irregular motor resistance (
)
Check of circuit breaker
and fuse.
Gas leakage of feeler
bulb of thermostat.
Check control switch.
Fan only fails to start.
Improper wiring.
Defect of fan motor
capacitor.
Replacement of fan motor.
Regular but fails to start.
Replacement of compressor.
(Locking of piston, metal.)
Irregular motor
resistance (
)
Irregular motor
insulation (
)