LG LWHD8008R Service Manual - Page 4

Preface - installation

Page 4 highlights

1-1. PREFACE This service manual provides various service information, including the mechanical and electrical parts, etc. This room air conditioner was manufactured and assembled under a strict quality control system. The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit. 1.1 FEATURES • DESIGNED FOR COOLING ONLY • POWERFUL AND INCREDIBLE COOLING • TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE • BUILT-IN ADJUSTABLE THERMOSTAT • WASHABLE ONE-TOUCH FILTER • COMPACT SIZE 1.2 SPECIFICATIONS ITEMS MODELS COOLING CAPACITY (BTU/h) POWER SUPPLY (Phase, V, Hz) INPUT (W) OPERATING CURRENT (AMP.) REFRIGERANT CONTROL REFRIGERANT CHARGE (R-22) INSIDE FAN OUTSIDE FAN AIR DISCHARGE CHASSIS PROTECTOR TEMPERATURE CONTROL ROTARY SWITCH FAN MOTOR RADS-51B 5,100 1ø, 115V, 60HZ 475 4.4 CAPILLARY TUBE 280g (9.9 oz) TURBO FAN PROPELLER FAN WITH SLINGER RING 2-WAY (RIGHT AND LEFT) TOP-DOWN • OVERLOAD PROTECTOR FOR COMPRESSOR • INTERNAL PROTECTOR FOR FAN MOTOR THERMOSTAT 5 STEP (LOW FAN, HIGH FAN, OFF, HIGH COOL, LOW COOL) 6 POLES, 16W -3-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

—3—
1-1. PREFACE
This service manual provides various service information, including the mechanical and electrical parts, etc.
This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.
1.1 FEATURES
• DESIGNED FOR COOLING ONLY
• POWERFUL AND INCREDIBLE COOLING
TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
• BUILT-IN ADJUSTABLE THERMOSTAT
• WASHABLE ONE-TOUCH FILTER
• COMPACT SIZE
1.2 SPECIFICATIONS
MODELS
ITEMS
COOLING CAPACITY (BTU/h)
5,100
POWER SUPPLY (Phase,V, Hz)
1ø, 115V, 60HZ
INPUT (W)
475
OPERATING CURRENT (AMP.)
4.4
REFRIGERANT CONTROL
CAPILLARY TUBE
REFRIGERANT CHARGE (R-22)
280g (9.9 oz)
INSIDE FAN
TURBO FAN
OUTSIDE FAN
PROPELLER FAN WITH SLINGER RING
AIR DISCHARGE
2-WAY (RIGHT AND LEFT)
CHASSIS
TOP-DOWN
PROTECTOR
TEMPERATURE CONTROL
THERMOSTAT
ROTARY SWITCH
FAN MOTOR
6 POLES, 16W
• OVERLOAD PROTECTOR FOR COMPRESSOR
• INTERNAL PROTECTOR FOR FAN MOTOR
5 STEP (LOW FAN, HIGH FAN, OFF, HIGH COOL, LOW COOL)
RADS-51B