Lantronix EDS16PS EDS - User Guide - Page 65
Flush Serial Data, Block Network, Password, Email on Connect, Submit.
View all Lantronix EDS16PS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
9: Line and Tunnel Settings Tunnel - Accept Mode Settings (continued) Flush Serial Data Block Serial Data Block Network Password Email on Connect Email on Disconnect Description Select Enabled to flush the serial data buffer on a new connection. Select On to block, or not tunnel, serial data transmitted to the device. Select On to block, or not tunnel, network data transmitted to the device. Enter a password that clients must send to the device within 30 seconds from opening a network connection to enable data transmission. The password can have up to 31 characters and must contain only alphanumeric characters and punctuation. When set, the password sent to the device must be terminated with one of the following: (a) 0x0A (LF), (b) 0x00, (c) 0x0D 0x0A (CR LF), or (d) 0x0D 0x00. Select whether the device sends an email when a connection is made. Select None if you do not want to send an email. Otherwise, select the Email profile to use for sending. Select whether the device sends an email when a connection is closed. Select None if you do not want to send an email. Otherwise, select the Email profile to use for sending. 5. Click Submit. 6. Repeat above steps as desired, according to additional tunnel(s) available on your product. EDS User Guide 65