Lantronix SGX 5150 IoT Device Gateway SGX 5150 User Guide - Page 137

Email on Disconnect, Prompt for Password

Page 137 highlights

9: Administration Tunnel Accept Mode Settings (continued) Initial Send Flush Serial Block Serial Block Network Password Email on Connect Email on Disconnect Description Enter the Initial Send data to be sent out the network upon connection establishment before any data from the Line. It may contain one or more Directives of the form %. The Initial Send string can be entered in Text or Binary form. The Binary form allows square braces [ ] to enclose one or more character designations separated by commas. Use straight decimal numbers up to 255 or hexadecimal numbers prefixed with 0x up to 0xFF within the square braces. To specify an open brace in binary mode, use two in a row. Example (in Binary mode): AB[255,0xFF]C[[D]Results in a string containing binary values where the dots appear: AB··C[D] Directives  %i local IP address  %m MAC address  %n network interface name  %p local port  %s serial number  %% % Set whether the serial line data buffer is flushed upon a new network connection. Choices are:  Enabled = serial data buffer is flushed on network connection  Disabled = serial data buffer is not flushed on network connection (default) Set whether Block Serial is enabled for debugging purposes. Choices are:  Enabled = if Enabled, incoming characters from the serial line will not be forwarded to the network. Instead, they will be buffered and will eventually flow off the serial line if hardware or software flow control is configured.  Disabled = this is the default setting; incoming characters from the Serial Line are sent on into the network. Any buffered characters are sent first. Set whether Block Network is enabled for debugging purposes. Choices are:  Enabled = if Enabled, incoming characters from the network will not be forwarded to the Serial Line. Instead, they will be buffered and will eventually flow off the network side.  Disabled = this is the default setting; incoming characters from the networkare sent on into the Serial Line. Any buffered characters are sent first. Enter a password. This password can be up to 31 characters in length and must contain only alphanumeric characters and punctuation. When set, clients must send the correct password string to the unit within 30 seconds from opening network connection in order to enable data transmission. The password sent to the unit must be terminated with one of the following:  0A (Line Feed)  00 (Null)  0D 0A (Carriage Return/Line Feed)  0D 00 (Carriage Return/Null) If, Prompt for Password is set to Enabled and a password is provided, the user will be prompted for the password upon connection. Select an email profile number to which an email notification will be sent upon the establishment of an accept mode tunnel. Select an email profile number to which an email notification will be sent upon the disconnection of an accept mode tunnel. SGX TM 5150, SGX TM 5150 MD, and SGX TM 5150 XL IoT Device Gateway User Guide 137

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171

9: Administration
SGX
5150, SGX
5150 MD, and SGX
5150 XL IoT Device Gateway User Guide
137
TM
TM
TM
Initial Send
Enter the
Initial Send
data to be sent out the network upon connection
establishment before any data from the Line. It may contain one or more
Directives
of the form
%<char>
.
The Initial Send string can be entered in
Text
or
Binary
form. The Binary form
allows square braces
[ ]
to enclose one or more character designations
separated by commas. Use straight decimal numbers up to 255 or hexadecimal
numbers prefixed with
0x
up to
0xFF
within the square braces. To specify an
open brace in binary mode, use two in a row. Example (in Binary mode):
AB[255,0xFF]C[[D]
Results in a string containing binary values where
the dots appear:
AB··C[D]
Directives
%i
local IP address
%m
MAC address
%n
network interface name
%p
local port
%s
serial number
%%
%
Flush Serial
Set whether the serial line data buffer is flushed upon a new network
connection. Choices are:
Enabled
= serial data buffer is flushed on network connection
Disabled
= serial data buffer is not flushed on network connection (
default
)
Block Serial
Set whether Block Serial is enabled for debugging purposes. Choices are:
Enabled
= if Enabled, incoming characters from the serial line will not be
forwarded to the network. Instead, they will be buffered and will eventually
flow off the serial line if hardware or software flow control is configured.
Disabled
= this is the default setting; incoming characters from the Serial
Line are sent on into the network. Any buffered characters are sent first.
Block Network
Set whether Block Network is enabled for debugging purposes. Choices are:
Enabled
= if Enabled, incoming characters from the network will not be
forwarded to the Serial Line. Instead, they will be buffered and will eventually
flow off the network side.
Disabled
= this is the default setting; incoming characters from the
networkare sent on into the Serial Line. Any buffered characters are sent
first.
Password
Enter a password. This password can be up to 31 characters in length and must
contain only alphanumeric characters and punctuation. When set, clients must
send the correct password string to the unit within 30 seconds from opening
network connection in order to enable data transmission. The password sent to
the unit must be terminated with one of the following:
0A (Line Feed)
00 (Null)
0D 0A (Carriage Return/Line Feed)
0D 00 (Carriage Return/Null)
If,
Prompt for Password
is set to
Enabled
and a password is provided, the
user will be prompted for the password upon connection.
Email on Connect
Select an email profile number to which an email notification will be sent upon
the establishment of an accept mode tunnel.
Email on Disconnect
Select an email profile number to which an email notification will be sent upon
the disconnection of an accept mode tunnel.
Tunnel Accept Mode
Settings (continued)
Description