Lantronix SISGM1040-284-LRT Install Guide ALM (Alarm) LED The ALM (Alarm) LED lights if the monitored temperature or internal voltages are exceeded. Issue critical stage for High / Low Voltage alarm (Power A or B Voltage) Lit Alarm LED in RED Color if Test-point (max) < Volts or if Test-point (min) < Volts. V1 (PHY, TTL, LED, SFP): (max: 3.465V, min: 3.135V) (+- 5%) V2 (MAC): (max: 2.625V, min: 2.375V) (+- 5%) V3 (MAC, DDR): (max: 1.575V, min: 1.425V) (+- 5%) V4 (MAC): (max: 1.05V, min: 0.95V) (+- 5%) Issue critical stage for High Temperature alarm: Lit Alarm LED in RED Color if Test-point (max) < temperature max: 100'C. You can view temperature and voltage settings at Monitor > Port > SFP Detail Info. You can you view and configure current trap event severity parameters via the Web Interface at Configuration > System > Alarm Notification > Trap Event Severity. See the Web User Guide for more information. 33808 Rev. E https://www.lantronix.com/ 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

Lantronix
SISGM1040-284-LRT Install Guide
33808 Rev. E
16
ALM (Alarm) LED
The
ALM
(Alarm) LED lights if the monitored temperature or internal voltages are exceeded.
Issue critical stage for High / Low
Voltage
alarm (Power A or B Voltage)
Lit Alarm LED in RED Color if Test-point (max) < Volts or if Test-point (min) < Volts.
V1 (PHY, TTL, LED, SFP): (max: 3.465V, min: 3.135V) (+- 5%)
V2 (MAC): (max: 2.625V, min: 2.375V) (+- 5%)
V3 (MAC, DDR): (max: 1.575V, min: 1.425V) (+- 5%)
V4 (MAC): (max: 1.05V, min: 0.95V) (+- 5%)
Issue critical stage for High
Temperature
alarm: Lit Alarm LED in RED Color if Test-point (max) < temperature
max: 100'C.
You can view temperature and voltage settings at
Monitor
>
Port
>
SFP
Detail
Info
.
You can you view and configure current trap event severity parameters via the Web Interface at
Configuration
>
System >
Alarm
Notification
>
Trap
Event
Severity
. See the Web User Guide for more information.