Lantronix TN-SFP-xxx User Guide Vcc Mon1 (Bias) Mon2 (TX PWR) Mon3 (RX PWR) Displays the internally measured transceiver supply voltage. Accuracy is vendor specific but must be better than 3 percent of the manufacturer's nominal value over specified operating temperature and voltage. Note that in some transceivers, transmitter supply voltage and receiver supply voltage are isolated. In that case, only one supply is monitored. Refer to the device specification for more detail. Displays the measured TX bias current in uA. Accuracy is vendor specific but must be better than 10 percent of the manufacturer's nominal value over specified operating temperature and voltage. Displays the measured coupled TX output power in mW. Accuracy is vendor specific but must be better than 3dB over specified operating temperature and voltage. Data is assumed to be based on measurement of a laser monitor photodiode current. Data is not valid when the transmitter is disabled. Displays the measured received optical power in mW. Absolute accuracy is dependent upon the exact optical wavelength. For the vendor specified wavelength, accuracy should be better than 3dB over specified temperature and voltage. This accuracy should be maintained for input power levels up to the lesser of maximum transmitted or maximum received optical power per the appropriate standard. It should be maintained down to the minimum transmitted power minus cable plant loss (insertion loss or passive loss) per the appropriate standard. Absolute accuracy beyond this minimum required received input optical power range is vendor specific. Compliance Information Class I Laser Compliance This product has been tested and found to comply with the limits for FDA Class I laser for IEC60825, EN60825, and 21CFR1040 specifications. Translated Safety Warnings Warning Class I laser product. Waarschuwing Klasse-I laser produkt. Varoitus Luokan I lasertuote. Attention Produit laser de classe I Warnung Laserprodukt der Klasse I. Avvertenza Prodotto laser di Classe I. Advarsel Laserprodukt av klasse I. Aviso Produto laser de classe I. ¡Advertencia! Producto láser Clase I. Varning! Laserprodukt av klass I. Aviso Produto a laser de classe I. Advarsel Klasse I laserprodukt. FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense. 33477 Rev. G https://www.lantronix.com/ Page 13 of 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

Lantronix
TN-SFP-xxx User Guide
33477 Rev. G
Page 13 of 15
Vcc
Displays the internally measured transceiver supply voltage. Accuracy is vendor
specific but must be better than 3 percent of the manufacturer's nominal value over
specified operating temperature and voltage. Note that in some transceivers,
transmitter supply voltage and receiver supply voltage are isolated. In that case,
only one supply is monitored. Refer to the device specification for more detail.
Mon1 (Bias)
Displays the measured TX bias current in uA. Accuracy is vendor specific but must be
better than 10 percent of the manufacturer's nominal value over specified operating
temperature and voltage.
Mon2 (TX PWR)
Displays the measured coupled TX output power in mW. Accuracy is vendor specific
but must be better than 3dB over specified operating temperature and voltage. Data
is assumed to be based on measurement of a laser monitor photodiode current.
Data is not valid when the transmitter is disabled.
Mon3 (RX PWR)
Displays the measured received optical power in mW. Absolute accuracy is
dependent upon the exact optical wavelength. For the vendor specified wavelength,
accuracy should be better than 3dB over specified temperature and voltage. This
accuracy should be maintained for input power levels up to the lesser of maximum
transmitted or maximum received optical power per the appropriate standard. It
should be maintained down to the minimum transmitted power minus cable plant
loss (insertion loss or passive loss) per the appropriate standard. Absolute accuracy
beyond this minimum required received input optical power range is vendor
specific.
Compliance Information
Class I Laser Compliance
This product has been tested and found to comply with the limits for FDA Class I laser for IEC60825, EN60825,
and 21CFR1040 specifications.
Translated Safety Warnings
Warning
Class I laser product.
Advarsel
Laserprodukt av klasse I.
Waarschuwing
Klasse-I laser produkt.
Aviso
Produto laser de classe I.
Varoitus
Luokan I lasertuote.
¡Advertencia!
Producto láser Clase I.
Attention
Produit laser de classe I
Varning!
Laserprodukt av klass I.
Warnung
Laserprodukt der Klasse I.
Aviso
Produto a laser de classe I.
Avvertenza
Prodotto laser di Classe I.
Advarsel
Klasse I laserprodukt.
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at the user's own expense.