Bluetooth Continuous Mode Testing The steps in http://www.cypress.com/file/298091/download describe how to run the Lantronix xPico 200 Bluetooth continuous mode scripts. These scripts are based on the Cypress mybluetool commands for the Cypress processor inside of the xPico 200 module. Loading BT Continuous Firmware Download the continuous mode BT firmware using the same process as used to load the continuous Wi-Fi firmware. Once downloaded and powered up, you will no longer be able to load the standard Lantronix firmware and the module can only be used for continuous mode testing for certification. 1. Download the xPico 200 continuous mode software at https://www.lantronix.com/products/xpico-200/#docs-downloads/. 2. Copy the xPico200_bt_test directory to the desktop on your PC. 3. Connect the Olimex ARM_USB_Tiny_H adapter to your PC and UUT. Note: You will need the Tag-Connect adapter and cable to connect your Olimex to the JTAG port on the evaluation board. Required Tag Connect part numbers TC2050-ARM2010 and TC2050-IDC. 4. Install the appropriate Zadig driver for the Olimex on your PC. 5. Open a command prompt and CD to directory: ..\Desktop\xPico200_bt_test\bt 6. Power up the unit and run the loadfw.bat script to load the continuous mode firmware. Running the BT Test Modes 1. Follow the instructions for each type of test in the Cypress document: http://www.cypress.com/file/298091/download 2. You will need to set the COM port to the COM port on your PC set MBT_COM_PORT=COMxx (where COMxx is the comport on your PC) set MBT_BAUD_RATE=3000000 (this should equal the baud rate for your COM port) 3. Power up the unit. 4. Assert the module reset pin and then wait 10 seconds. 5. Run the mbt reset command to reset the unit. 6. Make sure the reset command results with success per the message example for the reset test in the Cypress document. 7. Choose which of the BT tests you need to run and follow the command sequences in the Cypress document. xPico® 200 Certification Firmware Instructions 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

xPico
®
200 Certification Firmware Instructions
11
Bluetooth Continuous Mode Testing
The steps in
describe how to run the Lantronix
xPico 200 Bluetooth continuous mode scripts.
These scripts are based on the Cypress
mybluetool
commands for the Cypress processor inside of the xPico 200 module.
Loading BT Continuous Firmware
Download the continuous mode BT firmware using the same process as used to load the
continuous Wi-Fi firmware. Once downloaded and powered up, you will no longer be able to load
the standard Lantronix firmware and the module can only be used for continuous mode testing for
certification.
1.
Download the xPico 200 continuous mode software at
.
2. Copy the
xPico200_bt_test
directory to the desktop on your PC.
3. Connect the
Olimex ARM_USB_Tiny_H
adapter to your PC and UUT.
Note:
You will need the Tag-Connect adapter and cable to connect your Olimex to
the JTAG port on the evaluation board. Required Tag Connect part numbers
TC2050-ARM2010 and TC2050-IDC.
4. Install the appropriate
Zadig
driver for the Olimex on your PC.
5.
Open a command prompt and CD to directory:
..\Desktop\xPico200_bt_test\bt
6.
Power up the unit and run the
loadfw.bat
script to load the continuous mode
firmware.
Running the BT Test Modes
1.
Follow the instructions for each type of test in the Cypress document:
2.
You will need to set the COM port to the COM port on your PC
set MBT_COM_PORT=COMxx
(where
COMxx
is the comport on your PC)
set MBT_BAUD_RATE=3000000
(this should equal the baud rate for your COM port)
3.
Power up the unit.
4.
Assert the module reset pin and then wait 10 seconds.
5. Run the
mbt reset
command to reset the unit.
6.
Make sure the reset command results with success per the message example for the
reset test in the Cypress document.
7.
Choose which of the BT tests you need to run and follow the command sequences in the
Cypress document.