Diagnostic Error Code 080-198-XXX Game Port interface test aborted 080-199-XXX Game Port interface test failed, cause unknown 086-000-XXX Mouse Port interface Test Passed 086-001-XXX Mouse Port interface Presence 086-032-XXX Mouse Port interface Device controller failure 086-035-XXX Mouse Port interface Reset 086-040-XXX Mouse Port interface IRQ failure 086-195-XXX Mouse Port interface Test aborted by user 086-196-XXX Mouse Port interface test halt, error threshold exceeded 086-197-XXX Mouse Port interface test warning 086-198-XXX Mouse Port interface test aborted FRU/Action 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, "Using the Setup Utility," on page 49 2. Flash the system and re-test. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 162 3. Go to "Undetermined problems" on page 78 1. See "Undetermined problems" on page 78 2. Flash the system and re-test. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 162 3. Replace component under function test No action 1. Mouse 2. System board 1. Mouse 2. System board 1. Mouse 2. System board 1. Run Setup 2. Mouse 3. System board Information only Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, "Using the Setup Utility," on page 49 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, "Using the Setup Utility," on page 49 2. Flash the system and re-test. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 162 3. Go to "Undetermined problems" on page 78 68 Hardware Maintenance Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174

Diagnostic
Error
Code
FRU/Action
080-198-XXX
Game
Port
interface
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled.
See
Chapter
6,
“Using
the
Setup
Utility,”
on
page
49
2.
Flash
the
system
and
re-test.
See
“Updating
(flashing)
BIOS
from
a
CD-ROM
or
diskette”
on
page
162
3.
Go
to
“Undetermined
problems”
on
page
78
080-199-XXX
Game
Port
interface
test
failed,
cause
unknown
1.
See
“Undetermined
problems”
on
page
78
2.
Flash
the
system
and
re-test.
See
“Updating
(flashing)
BIOS
from
a
CD-ROM
or
diskette”
on
page
162
3.
Replace
component
under
function
test
086-000-XXX
Mouse
Port
interface
Test
Passed
No
action
086-001-XXX
Mouse
Port
interface
Presence
1.
Mouse
2.
System
board
086-032-XXX
Mouse
Port
interface
Device
controller
failure
1.
Mouse
2.
System
board
086-035-XXX
Mouse
Port
interface
Reset
1.
Mouse
2.
System
board
086-040-XXX
Mouse
Port
interface
IRQ
failure
1.
Run
Setup
2.
Mouse
3.
System
board
086-195-XXX
Mouse
Port
interface
Test
aborted
by
user
Information
only
Re-start
the
test,
if
necessary
086-196-XXX
Mouse
Port
interface
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
086-197-XXX
Mouse
Port
interface
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled.
See
Chapter
6,
“Using
the
Setup
Utility,”
on
page
49
2.
Re-run
test
3.
Replace
the
component
that
is
called
out
in
warning
statement
4.
Replace
the
component
under
test
086-198-XXX
Mouse
Port
interface
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled.
See
Chapter
6,
“Using
the
Setup
Utility,”
on
page
49
2.
Flash
the
system
and
re-test.
See
“Updating
(flashing)
BIOS
from
a
CD-ROM
or
diskette”
on
page
162
3.
Go
to
“Undetermined
problems”
on
page
78
68
Hardware
Maintenance
Manual