LevelOne IES-1084 Manual - Page 16
Installation
View all LevelOne IES-1084 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Installation This chapter gives step-by-step instructions about how to install the switch: Selecting a Site for the Switch As with any electric device, you should place the switch where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements: - The ambient temperature should be between -40℃ to 75℃ (-40℉ to 167℉). - The relative humidity should be less than 95 percent, non-condensing. - Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards. - Make sure that the switch receives adequate ventilation. Do not block the ventilation holes on each side of the switch. Wiring Diagram Field Wiring Terminal Markings: Use Copper Conductors Only, 60/75℃, wire range 12-24 AWG, torque value 7 lb-in. IES-1084 User Manual Page 16