Parallel Wrap Test, To run the Parallel Wrap Test
View all Lexmark Optra C710 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 209 highlights
5016-001 Parallel Wrap Test This test is used with a wrap plug to check operation of the parallel port hardware. Each parallel signal is tested. To run the Parallel Wrap Test: 1. Disconnect the parallel interface cable and install the wrap plug (P/N 1319128). 2. Select the Parallel Wrap Test from the menu.The power indicator blinks indicating the test is in progress. The test runs continuously until canceled. When the test finishes, the screen updates. If the test passes, the Pass Count increases by 1, however if the test fails, one of the following messages display for approximately 3 seconds: Sync Busy Error Interrupt Request Error Strobe Interrupt Request Error Init Fail Error Init Busy Error Init Rise Error Host Busy Error RAM Data FF Error RAM Data AA Error RAM Data 00 Error RAM Data 55 Error DMA Count Error DMA Address Error DMA Interrupt Error DMA Memory Error DMA Background Error Clear Init Rise Error False Init Rise Error Autofeed Rising Interrupt Error Clear Autofeed Rise Error False Autofeed Rise Error Autofeed Falling Interrupt Error Clear Autofeed Fall Error Once the maximum count is reached the test stops. The power indicator goes on solid and the final results display. Press Return/Stop to exit the test. Diagnostic Aids 3-11