Lexmark T620 Technical Reference - Page 37
PCL Emulation Commands, PCL Emulation Commands by Function
View all Lexmark T620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
2-25 PCL PCL Emulation Commands See the following tables for a listing of the commands grouped by function. To determine which commands your printer supports, see Table A-1: "PCL Emulation Commands" on page A-1. PCL Emulation Commands by Function Table 2-14: Job Control Command / Parameters ESCE ESC&d#A 0 = Collation off 1 ... 999 (number of Copies) l ESC& #X # = number of Copies (1 to 32767) Default = 1 l ESC& #S 0 Single-Sided (Default) 1 Duplex Long-Edge Binding 2 Duplex Short-Edge Binding l ESC& #U # = number of Decipoints Range = -32767 to 32767 (1 Decipoint = 1/720 inch) Default = 0 l ESC& #Z # = number of Decipoints Range = -32767 to 32767 (1 Decipoint = 1/720 inch) Default = 0 Function / Result Printer Reset • Prints any partial pages. • Resets printer environment to defaults. • Deletes all temporary downloaded resources. Number of Collated Copies Turns collation of pages off or sets the number of collated copies. Number of Copies Affects the page currently in process and subsequent pages. Simplex/Duplex Print Long-edge or short-edge binding refers to the side of the physical page where binding occurs. Long-Edge Offset Registration Also known as Left Offset. Adjusts placement of logical page along the width of the physical page. Short-Edge Offset Registration Also known as Top Offset. Adjusts placement of logical page along the length of the physical page.