Maintenance - sliding gate operator

Page 4 highlights

MAINTENANCE DESCRIPTION Entrapment Protection Devices Warning Signs Gate Drive Chain (Slide Only) CHECK AT LEAST ONCE EVERY MONTH TASK Check and test for proper operation Make sure they are present Inspect for wear or damage Check for excessive slack and lubricate The following should be checked by an authorized LiftMaster dealer: DESCRIPTION Manual Disconnect Sprockets and Chains Belt and Pulley (Slide Only) Accessories Electrical Chassis Mounting Bolts Operator Batteries TASK Check and test for proper operation Check for excessive slack and lubricate Check for excessive slack, wear, or damage Check all for proper operation Inspect all wire connections Check for tightness Inspect for wear or damage Replace CHECK AT LEAST ONCE EVERY 6 MONTHS X X 3 YEARS X X X X X X BATTERIES Batteries will degrade over time depending on temperature and usage. For best performance, the batteries should be replaced every 3 years. Use only LiftMaster part 29-NP712 for replacement batteries. The operator comes with two 7AH batteries. Two 33AH (A12330SGLPK) may be used in place of the 7AH batteries. The batteries contain lead and need to be disposed of properly. Batteries do not perform well in extremely cold temperatures. NOTE: If your application includes a heater, two 33AH will not fit into the operator enclosure (swing only). The operator alarm will beep 3 times with a command if the battery is low. DRIVE CHAIN (SLIDE ONLY) Over time, the drive chain on the operator will stretch and need to be tightened. To tighten the drive chain adjust either of the two chain eye bolts. NOTE: The chain should have no more than 1 inch of sag for every 10 feet of chain length. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

3
MAINTENANCE
The following should be checked by an authorized LiftMaster dealer:
BATTERIES
Batteries will degrade over time depending on temperature and usage. For best performance, the batteries should
be replaced every 3 years. Use only LiftMaster part 29-NP712 for replacement batteries. The operator comes with
two 7AH batteries. Two 33AH (A12330SGLPK) may be used in place of the 7AH batteries.
The batteries contain lead and need to be disposed of properly. Batteries do not perform well in extremely cold
temperatures.
NOTE:
If your application includes a heater, two 33AH will not fit into the operator enclosure (swing only).
The operator alarm will beep 3 times with a command if the battery is low.
DRIVE CHAIN (SLIDE ONLY)
Over time, the drive chain on the operator will stretch and need to be tightened. To tighten the drive chain adjust
either of the two chain eye bolts.
NOTE:
The chain should have no more than 1 inch of sag for every 10 feet of chain length.
CHECK AT LEAST ONCE EVERY MONTH
DESCRIPTION
TASK
Entrapment Protection Devices
Check and test for proper operation
Warning Signs
Make sure they are present
Gate
Inspect for wear or damage
Drive Chain (Slide Only)
Check for excessive slack and lubricate
CHECK AT LEAST ONCE EVERY
DESCRIPTION
TASK
6 MONTHS
3 YEARS
Manual Disconnect
Check and test for proper operation
X
Sprockets and Chains
Check for excessive slack and
lubricate
X
Belt and Pulley (Slide
Only)
Check for excessive slack, wear, or
damage
X
Accessories
Check all for proper operation
X
Electrical
Inspect all wire connections
X
Chassis Mounting Bolts
Check for tightness
X
Operator
Inspect for wear or damage
X
Batteries
Replace
X