LiftMaster GH GH -Mechanical New style w/ thermal overload change Manual - Page 8

Adjustment, Install Ation - door opener

Page 8 highlights

I N S TA L L AT I O N ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) PHOTO EYES & SENSING EDGES Sensing devices provided for door industry type operators with an isolated normally open (N.O.) dry contact output are compatible with your operator. This includes pneumatic and electric edges, and through beam and retro reflective photo eyes. If you would like to order or receive more information on safety devices, please contact your local Authorized Dealer. If not pre-installed by the door manufacturer, mount the sensing edge on the door according to the instructions provided with the edge. The sensing edge may be electrically connected by either coiled cord or take-up reel. WARNING To reduce the risk of SEVERE INJURY or DEATH, ALWAYS CAUTION install reversing sensors when the 3-button control station is out of sight of door or ANY other control (automatic or manual) is used. Reversing devices are recommended for ALL installations. WIRING For wiring of your sensing device to the operator, refer to the wiring diagrams provided on pages 13 and 14. See field connection terminals identified as sensing device or safety edge. IMPORTANT NOTES: a. Proceed with limit switch adjustments described below before making any sensing edge wiring connections to operator. b. Electrician must hardwire the junction box to the operator electrical box in accordance with local codes. TAKE-UP REEL Take-up reel should be installed 12" (30.48 cm) above the top of the door. AVERTISSEMENT COIL CORD Connect operator end of coil cord to junction box (not provided) ATTENTION fastened to the wall approximately halfway up the door opening. WARNING ADJUSTMENT WARNING LIMICT SAWUITCTHIOADNJUSTMENT NOTE: Make sure the limit nuts are positioned between the limit switches before proceeding with adjustments. 1. Depress retaining plate to allow nut to spin freely. After adjustment, release plate and move nut back and forth to ensure it is fully seated in slot. 2. To increase door travel, spin nut away from limit switch. To decrease door travel, spin limit nut toward limit switch. 3. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. 4. Repeat steps 1 and 2 for close cycle. Adjust close limit nut so that the limit switch is engaged as door fully seats at the floor. WARNING To avoid SERIOUS personal INJURY or DEATH from electrocution, disconnect electric power BEFORE manually moving limit nuts. AVERTISSEMENT AAVEDRVTEIRSOPTSENEELimNMit SCwEitcIhNAT CLOSE Limit Switch ATTENTION PARVEECRATUISACctSuaItoEÓr MNENT SAFETY (Aux. Close) Limit Switch 8 Retaining Plate SAFETY (Aux. Open) Limit Switch

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

8
ENTRAPMENT PROTECTION ACCESSORIES
(OPTIONAL)
PHOTO EYES & SENSING EDGES
Sensing devices provided for door industry type operators with an
isolated normally open (N.O.) dry contact output are compatible
with your operator. This includes pneumatic and electric edges,
and through beam and retro reflective photo eyes. If you would
like to order or receive more information on safety devices, please
contact your local Authorized Dealer.
If not pre-installed by the door manufacturer, mount the sensing
edge on the door according to the instructions provided with the
edge. The sensing edge may be electrically connected by either
coiled cord or take-up reel.
IMPORTANT NOTES:
a.
Proceed with limit switch adjustments described below before
making any sensing edge wiring connections to operator.
b.
Electrician must hardwire the junction box to the operator
electrical box in accordance with local codes.
WIRING
For wiring of your sensing device to the operator, refer to the
wiring diagrams provided on pages 13 and 14. See field
connection terminals identified as sensing device or safety edge.
TAKE-UP REEL
Take-up reel should be installed 12" (30.48 cm) above the top of
the door.
COIL CORD
Connect operator end of coil cord to junction box (not provided)
fastened to the wall approximately halfway up the door opening.
ADJUSTMENT
To avoid SERIOUS personal INJURY or DEATH from
electrocution, disconnect electric power BEFORE manually
moving limit nuts.
WARNING
WARNING
LIMIT SWITCH ADJUSTMENT
NOTE:
Make sure the limit nuts are positioned between the limit
switches before proceeding with adjustments.
1.
Depress retaining plate to allow nut to spin freely. After
adjustment, release plate and move nut back and forth to
ensure it is fully seated in slot.
2.
To
increase
door travel, spin nut
away
from limit switch. To
decrease
door travel, spin limit nut
toward
limit switch.
3.
Adjust open limit nut so that door will stop in open position
with the bottom of the door even with top of door opening.
4.
Repeat steps 1 and 2 for close cycle. Adjust close limit nut so
that the limit switch is engaged as door fully seats at the floor.
INSTALL ATION
To reduce the risk of SEVERE INJURY or DEATH, ALWAYS
install reversing sensors when the 3-button control station is
out of sight of door or ANY other control (automatic or
manual) is used. Reversing devices are recommended for ALL
installations.
WARNING
WARNING
SAFETY
(Aux. Close) Limit Switch
CLOSE
Limit Switch
OPEN
Limit Switch
Actuator
Retaining Plate
SAFETY